Instruction Sheet

4
4. Test the gas pressure regulator and gas supply line.
The regulator must be checked at a minimum 1" (2.5 cm)
water column above the set pressure. The inlet pressure to
the regulator should be as follows for operation and checking
the regulator setting:
LP Gas:
Minimum pressure 10" (25.4 cm) W.C.P.
Supply pressure 14" (35.5 cm) W.C.P.
Gas Supply Pressure Testing
Line pressure testing above ½ psi gauge (14" WCP)
The cooktop and its individual shutoff valve must be
disconnected from the gas supply piping system during any
pressure testing of that system at test pressures in excess of
½ psi (3.5 kPa).
Line pressure testing at ½ psi gauge (14" WCP) or lower
The cooktop must be isolated from the gas supply piping
system by closing its individual manual shutoff valve during
any pressure testing of the gas supply piping system at test
pressures equal to or less than ½ psi (3.5 kPa).
5. If the burner grates are installed, remove them.
Use the following charts to match the correct gas orifice spud
with the burner location and model being converted.
LP Gas Orifice Spud Chart for Kit W10676661
Burner Models for Kit W10676661
LP Gas Orifice Spud Chart for Kit W10676662
Burner Models for Kit W10676662
Burner locations
6. Remove all burner caps and burner bases (see the User
Guide for burner reference).
To remove the burner base for the Dual Flame and Dual Tier
Ultra Torch burners use a Torx
®
T10 driver to remove the screw.
Burner
Rating
Color Stamp
(A)
Size
5,000 BTU Green 66 0.66 mm
7,000 BTU White 75 0.75 mm
8,000 BTU Orange 79 0.79 mm
11,000 BTU Red 97 0.97 mm
13,000 BTU Yellow 108 1.08 mm
16,000 BTU Pink 115 1.15 mm
12,000 BTU
Inner
Outer
Brown
Brown
85
48
0.85 mm
0.48 mm
A. Size stamp
Model No. Left
Front
Left
Rear
Center
Inner
Center
Outer
Right
Rear
Right
Front
Inner
Right
Front
Outer
WCG51US0D
MGC7430D
ICS500DS00
66
Green
108
Yellow
N/A N/A 97
Red
75
White
75
White
WCG75US0D
MGC9530D
66
Green
115
Pink
N/A N/A 97
Red
75
White
75
White
WCG97US0D
KCGS350E
ICS655DS00
75
White
79
Orange
85
Brown
48
Brown
66
Green
75
White
75
White
WCG51US6D
MGC7536D
75
White
75
White
108
Yell ow
108
Yellow
66
Green
97
Red
97
Red
WCG97US6D
MGC9536D
KCGS356E
75
White
75
White
85
Brown
48
Brown
66
Green
97
Red
97
Red
Burner
Rating
Color Stamp
(A)
Size
5,000 BTU White 66 0.66 mm
A. Size stamp
6,000 BTU Green 70 0.70 mm
9,100 BTU Black 89 0.89 mm
11,000 BTU Orange 97 0.97 mm
13,000 BTU
Inner
Outer
Blue
Brown
45
97
0.45 mm
0.97 mm
14,000 BTU
Inner
Outer
Blue
Yell ow
45
101
0.45 mm
1.01 mm
16,000 BTU
Inner
Outer
Blue
Red
45
105
0.45 mm
1.05 mm
9,000 BTU
Inner
Outer
Pink
Pink
40
80
0.40 mm
0.80 mm
Model No. Left
Front
Left
Rear
Center
Inner
Center
Outer
Right
Rear
Right
Front
Inner
Right
Front
Outer
KCGS550E
66
White
89
Black
97
Brown
45
Blue
70
Green
89
Black
89
Black
KCGS556E
66
White
89
Black
101
Yellow
45
Blue
70
Green
89
Black
89
Black
KCGS950ES
66
White
89
Black
97
Brown
45
Blue
70
Green
80
Pink
40
Pink
KCGS956ES
66
White
97
Orange
105
Red
45
Blue
70
Green
80
Pink
40
Pink
A. Left front
B. Left rear
C. Center
D. Right rear
E. Right front
B
D
C
E
A