MSDS

SHENZHEN AOV TESTING TECHNOLOGY CO.,LTD
1-6/F,No.5,Yuantou Lane,Tanglang,Taoyuan Street, Nanshan District,Shenzhen,Guangdong,China
Tel: +86-755-8600 8000 Fax: +86-755-8600 8282 Http://www.aovt.com Postcode: 518055
Attention is drawn to the terms and conditions printed overleaf
MSDS
NO.: A001R130108029001 Date: Jan 11, 2013 Page 3 of 6
Section 4 - First Aid Measures
Skin touch: Remove contaminated clothes and rinse the skin with plenty of water.
Eyes touch: Lifting the upper and lower eyelids, flush the eyes with plenty of water or saline water. Get medical aid.
Inhalation: Remove from exposure and move to fresh air immediately. Keep the respiratory tract smooth. Use oxygen if
available. Get medical aid.
Ingestion: Drink sufficient hot water and induce vomiting. Get medical aid.
Section 5 - Fire Fighting Measures
Danger characteristic: Batteries may burst and release hazardous decomposition products when exposed to a fire situation.
Hazardous combustion products: CO, CO
2
Fire-Fighting method & media: The staff must equip with filtermask (full mask) or isolated breathing apparatus. The staff
must wear the clothes which can defense the fire and the toxic gas. Put out the fire in the upwind direction. Remove the
container to the open space as soon as possible. Spray water on the containers in the fireplace to keep them cool until finish
extinguishment. Media: hazy water, foam, powder, CO
2,
sandy clay.
Section 6 –Accidental Release Measures
Emergency treatment: If the battery material is released, remove personnel from area until fumes dissipate. Provide
maximum ventilation to clear out hazardous gases. Wipe it up with a cloth, and dispose of it in a plastic bag and put into a steel
can. The preferred response is to leave the area and allow the batteries to cool and vapors to dissipate. Provide maximum
ventilation. Avoid skin and eye contact or inhalation of vapors. Remove spilled liquid with absorbent and incinerate waste.
Section 7 - Handling and Storage
Handling: Closed operation. To supply with sufficient partial air exhaust. The operating staff must have received special
training and abide by the operating regulations. It is advised that the staff wear work clothes, respirator, chemical protective
glasses and gloves. Keep away from fire and heating sources. No smoking in the workplace. Avoid contacting with oxidizers
and acid. Do not expose the battery to excessive physical shock or vibration. Short-circuiting should be avoided. Place the cell
beyond the child’s reach. Take care when transport, prevent damaging the packing and container. Equip with relevant types
and quantities of extinguishment instruments and device for divulgence handling. Empty the container which may include
harmful material.
Storage: Keep the sample in the cool, dry and well-ventilated place. Keep away from fire and heating sources. Don’t keep the
samples with oxidizer and acid. Equip with relevant types and quantities of the extinguishment instruments. The storage place
should be equipped with suitable shelter materials for divulgence handling.
Section 8 - Exposure Controls, Personal Protection
Maximum admissible concentration: No standard yet
Monitoring Method: /
Engineering Control: Supply with sufficient partial air exhaust.
Respiratory Protection: Wear self-contained breathing filtermask (full mask) if the density exceed in the air. Wear breathing
apparatus under the condition of emergency rescue or evacuation.
Eyes Protection: Have been mentioned in the respiratory protection.
Body Protection: Wear fireproofing, gas defense clothes.