20 lb LP Gas Fuel Tank
A
To Connect the 20 lb LP Gas Fuel Tank:
1. Check that the 20 lb LP gas fuel tank is in the “Off”
position. If not, turn the valve clockwise until it stops.
2. Check that the 20 lb LP gas fuel tank valve has the
t
1t l lthd ti
A. Tank tray locking bracket
proper
t
ype-
1
ex
t
erna
l
ma
l
e
th
rea
d
connec
ti
ons per
ANSI Z21.81.
3. Check that the burner control knobs are in the “Off”
position.
4. Remove any debris and inspect the valve
connections, port, and gas pressure regulator/hose
assembly for damage.
LP Gas:
IMPORTANT: A 20 lb LP gas fuel tank must be purchased
separately.
IMPORTANT: The gas pressure regulator/hose assembly
supplied with the grill must be used Replacement gas pressure
NOTE: Always keep the LP cylinder at 90°(upright)
orientation to provide vapor withdrawal.
5. Using your hand, turn the gas pressure
regulator/hose assembly clockwise to connect to
th
e
2
0
l
b
LP
gas
f
ue
l t
a
nk
as
s
h
o
wn.
supplied
with
the
grill
must
be
used
.
Replacement
gas
pressure
regulator/hose assembly specific to your model is available from
your outdoor grill dealer.
Door Style Tank Tray
1. Open cabinet door.
2. Slide the tank tray locking bracket counterclockwise 90
degrees and pull out the tray.
e0b gasue a asso
Hand tighten only. Use of a wrench could damage the
quick coupling nut.
3. Place the 20 lb LP
g
as fuel tank bottom collar into the
A
A. Tank tray locking bracket
B. Tank Bolt
A. Gas pressure regulator/hose assembly
B. 20 lb LP gas fuel tank
A
B
B
g
mounting hole in the tank tray.
4. Tighten the tank bolt clockwise against the bottom collar
of the 20 lb LP gas fuel tank to secure.
A. Locking screw
Make sure that the cylinder valve connection device
properly mates with the connection device attached to
the inlet of the pressure regulator.
6. Open the tank valve fully by turning the valve
counterclockwise. Wait a few minutes for gas to
move through the gas line.
7. Before li
g
htin
g
the
g
rill
,
test all connections b
y
B. Mounting hole
C. Bottom collar
5. Slide the tank tray with the 20 lb LP gas fuel tank
back into the cabinet and lock the locking bracket.
BA.
C
gg g, y
brushing on an approved noncorrosive leak-
detection solution. The presence of bubbles will
show a leak.
18
W
ARNING
Explosion Hazard
Securely tighten all gas connections.
If connected to LP, have a qualified person make sure
gas pressure does not exceed 14” (36 cm) water
column.
Examples of a qualified person include:
licensed heating personnel,
authorized gas company personnel, and
authorized service personnel.
Failure to do so can result in death, explosion, or fire.