Installation Guide

Adjust High Flame Setting Screw
When converting from LP to Natural gas, you will need to
adjust the high flame setting screw for ideal burner flame
height.
1. Remove each control knob for the main burners and
side burner by pulling the control knob off.
Change the Side burner Orifice
1. Locate the Liquid propane orifice at the
end of the valve.
2. Use a 6 mm socket wrench or 6 mm nut driver to
remove the LP orifice. Replace with the Natural gas
orifice.
(
NG orifice comes with the
g
rill
p
acka
g
e
(gpg
contents)
A
2. Use a 6” flat-blade screwdriver to turn the high flame
setscrew counterclockwise approximate 90 degree.
IMPORTANT: Check that the orifice is properly installed
inside of the supply pipe.
3
Reinstall the orifice support and supply pipe and
3
.
Reinstall
the
orifice
support
and
supply
pipe
and
tighten the nut with a 24 mm wrench.
4. Reinstall the spider guard, access cover, and wind
baffle.
5. Test all connections using an approved noncorrosive leak
detection solution. Bubbles will show a leak. Correct any
leak found by calling technical support.
3. Check that burner operates at the new high flame
setting. It may be necessary to adjust the screw
setting slightly more to get the ideal burner flame
height.
leak
found
by
calling
technical
support.
22