Installation Guide

Product Dimension
Gas Supply Requirements
543,36
26. 2"
(66. 5cm)
12. 6"
(32cm)
50. 3"
(127. 8cm)
(32cm)
12. 6"
(32cm)
48. 4"
(122. 9cm)
Observe all governing codes and ordinances.
IMPORTANT: This installation must conform with all local
codes and ordinances. In the absence of local codes,
installation must conform with either the National Fuel Gas
Code, ANSI Z223.1/NFPA54, Natural Gas and Propane
Installation Code, CSA B149.1, Propane Storage And
584,19
23. 6"
(60cm)
The model/serial number rating plate is located on the
inside of the cabinet door. See the following illustration.
Handling Code, B149.2, or the Standard for Recreational
Vehicles, ANSI A119.2/NFPA 1192 and CSA Z240 RV Series
Recreational Vehicle Code as applicable.
IMPORTANT: Grill must be connected to a regulated gas
supply. Refer to the model/serial rating plate for information
on the type of gas that can be used. If this information does
not agree with the type of gas available, check with your
local
g
as su
pp
lier.
A
. Model/Seria
l
numbe
r
p
late
gpp
Gas Conversion:
No attempt shall be made to convert the grill from the gas
specified on the model/serial rating plate for use with a
different gas type without consulting the serving gas
supplier. The conversion kit supplied with grill must be used.
See “Gas Conversions” section for instructions.
Gas Pressure Regulator
The gas pressure regulator supplied with this grill must be
d
A
use
d
.
The inlet (supply) pressure to the regulator should be as
follows for proper operation:
LP Gas:
Operating pressure: 11" (27.9 cm) WCP
Inlet (supply) pressure: 11" to 14" (27.9 cm to 35.5 cm) WCP
Natural Gas:
Operating pressure: 4" (10.2 cm) WCP
Inlet (supply) pressure: 7
"
to 14
"
(178cmto355cm)WCP
Inlet
(supply)
pressure:
7
to
14
(17
.
8
cm
to
35
.
5
cm)
WCP
maximum.
Contact local gas supplier if you are not sure about the inlet
(supply) pressure.
6
W
ARNING
Explosion Hazard
Use a new CSA International approved “outdoor”
gas supply line.
Securely tighten all gas connections.
If connected to LP, have a qualified person make sure
gas pressure does not exceed 14” water
column.
Examples of a qualified person include:
licensed heating personnel,
authorized gas company personnel, and
authorized service personnel.
Failure to do so can result in death, explosion, or fire.
Install a shut-off valve.
(36cm)