Operation Manual

8
To ensure that the grill
operates properly, it is recommended
that the island have ventilation on all 4 sides as shown in the
following illustration. The ventilation holes should be as
diagrammed to ensure adequate ventilation for your grill and
island.
Proper ventilation is a req
uired based on the above mentioned
specifications for your grill to operate properly.
LP Gas
LP Gas Pressure Regul
ator/Hose Assembly Location
Measurements
shown are for attaching the LP gas pressure
regulator/hose assembly to the enclosure.
Natural Gas Conver
sion
Natural Gas Pressure Regulator Location
Measurements show
n are for attaching the Natrual gas pressure
regulator to the enclosure.
G
as S
u
pply
Requirements
Observe all governing
codes and ordinances.
IMPORTANT: This installation must conform with all local codes
and ordinances. In the absence of local codes, installation must
conform with American National Standard, National Fuel Gas
Code ANSI Z223.1 - latest edition or CAN/CGA B149.1 - latest
edition.
10 in.
2
(64.5 cm
2
) min.
ventilation both sides
2½" (6.0 cm) max.
1½" (3.0 cm) max.
20 in.
2
(129.0 cm
2
) min.
ventilation both sides
5" (12.7 cm) max.
!
!
WARNING
Explosion Hazard
Use a new CSA International approved “outdoor”
gas supply line.
Securely tighten all gas connections.
If connected to LP, have a qualified person make sure
gas pressure does not exceed 14” (3! cm) water
column.
Examples of a qualified person include:
licensed heating personnel,
authorized gas company personnel, and
authorized service personnel.
Failure to do so can result in death, explosion, or fire.
Install shut-off valve.