Owner's Manual
20
Base Grille Water Filtration System
Model T1WG2L/T2RFWG2 Capacity 200 Gallons (757 Liters)
Model T1WG2/T2RFWG2 Capacity 200 Gallons (757 Liters)
This system has been tested according to NSF/ANSI Standards 42 and 53 for the reduction of the substances listed below. The
concentration of the indicated substances in water entering the system was reduced to a concentration less than or equal to the
permissible limit for water leaving the system, as specied in NSF/ANSI Standards 42 and 53.
Substance Reduction
Aesthetic Effects
NSF
Reduction
Requirements
Average
Inuent
Inuent Challenge
Concentration
Maximum
Efuent
Average
Efuent
Minimum%
Reduction
Average%
Reduction
Chlorine Taste/Odor
Particulate Class II*
50% reduction
85% reduction
2.0182 mg/L
1333333 #/mL
2.0 mg/L ± 10%
At least
10,000 particles/mL
0.06 mg/L
6600 #/mL**
0.0536 mg/L
2325 #/mL
97.03%
99.51%
97.34%
99.83%
Contaminant
Reduction
NSF Reduction
Requirements
Average
Inuent
Inuent Challenge
Concentration
Maximum
Efuent
Average
Efuent
Minimum%
Reduction
Average%
Reduction
Lead: @ pH 6.5 ***
Lead: @ pH 8.5 ***
0.010 mg/L
0.010 mg/L
0.1533 mg/L
0.1400 mg/L
0.15 mg/L ± 10%
0.15 mg/L ± 10%
0.0005 mg/L
0.0007 mg/L
0.0005 mg/L
0.0006 mg/L
99.67%
99.50%
99.67%
99.57%
Mercury: @ pH 6.5
Mercury: @ pH 8.5
0.002 mg/L
0.002 mg/L
0.0058 mg/L
0.0059 mg/L
0.006 mg/L ± 10%
0.006 mg/L ± 10%
0.0002 mg/L
0.0005 mg/L
0.0002 mg/L
0.0003 mg/L
96.54%
91.57%
96.54%
94.92%
Benzene 0.005 mg/L 0.0154 mg/L 0.015 mg/L ± 10% 0.0012 mg/L 0.0006 mg/L 92.22% 96.34%
O-Dichlorobenzene 0.6 mg/L 1.7571 mg/L 1.8 mg/L ± 10% 0.0250 mg/L 0.0066 mg/L 98.58% 99.63%
Toxaphene 0.003 mg/L 0.015 mg/L 0.015 mg/L ± 10% 0.001 mg/L 0.001 mg/L 93.3% 93.3%
Carbofuran 0.040 mg/L 0.0819 mg/L 0.08 mg/L ± 10% 0.0400 mg/L 0.0213 mg/ 51.13% 74.00%
Test Parameters: pH = 7.5 ± 0.5 unless otherwise noted. Flow = 0.5 gpm (1.9 Lpm). Pressure = 60 psig (413.7 kPa).
Temp. = 68°F to 71.6°F (20°C to 22°C). Rated service capacity = 200 gallons (757 liters).
■ It is essential that operational, maintenance, and lter
replacement requirements be carried out for the product to
perform as advertised.
■ Use replacement lter T2RFWG2, part #4396841.
Model T1WG2L: Style 1 – When the lter indicator reads
10%, order a new lter. When the indicator reads 0%, it is
recommended that you replace the lter.
Style 2 – When the lter indicator changes from green to
yellow, order a new lter. When the indicator changes from
yellow to red, it is recommended that you replace the lter.
Style 3 – When the water lter status display changes from
“GOOD” to “ORDER,” order a new lter. When the lter
indicator reads “REPLACE,” it is recommended that you
replace the lter.
Style 4 – Press FILTER to check the status of your water lter.
If the lter indicator light is yellow, order a new lter. If the lter
indicator light is red, it is recommended that you replace the
lter.
Model T1WG2: Change the water lter cartridge every 6
months. If the water ow to the water dispenser or ice maker
decreases noticeably before 6 months have passed, replace
the water lter cartridge more often.
■ These contaminants are not necessarily in your water supply.
While testing was performed under standard laboratory
conditions, actual performance may vary.
■ The product is for cold water use only.
■ Do not use with water that is microbiologically unsafe or of
unknown quality without adequate disinfection before or after
the system.
■ Refer to the “Warranty” section for the Manufacturer’s name,
address and telephone number.
■ Refer to the “Warranty” section for the Manufacturer’s limited
warranty.
Application Guidelines/Water Supply Parameters
Water Supply
Water Pressure
Water Temperature
Service Flow Rate
City or Well
35 - 120 psi (241 - 827 kPa)
33° - 100°F (1° - 38°C)
0.5 gpm (1.9 L/min.) @ 60 psi*
System tested and certied by NSF International against NSF/ANSI Standard 42 for
the reduction of Chlorine Taste and Odor, Particulate Class II*; and against NSF/ANSI
Standard 53 for the reduction of Mercury, Benzene, Toxaphene, O-dichlorobenzene,
and Carbofuran.
*Class II particle size: 1 um to <5 um
**Test requirement is at least 100,000 particles/mL of AC Fine Test Dus
***Compliant for Lead reduction requirements under NSF/ANSI Standard 53 as tested by Pace Analytical Services, Inc.
®
NSF is a registered trademark of NSF International.