Use & Care Guide
Table Of Contents
- REFRIGERATOR SAFETY
- Refrigerator Safety
- MODEL
- Models
- MAINTENANCE AND CARE
- Cleaning
- Changing the LED Module
- Refrigeration Shelves and Door Bins
- Sabbath and Vacation Care
- INSTALLATION REQUIREMENTS
- Tools and Parts
- Location Requirements
- Electrical Requirements
- Water Supply Requirements
- Tipping Radius
- Product Dimensions
- Door Swing Dimensions
- Overlay Series Door Panel and Cabinetry Clearance
- Overlay Series Custom Panels and Handle Kits
- Stainless Series Custom Side Panels
- INSTALLATION INSTRUCTIONS
- Unpack the Refrigerator
- Connect the Water Supply
- Plug in Refrigerator
- Move Refrigerator to Final Location
- Level and Align Refrigerator
- Install Overlay Series Custom Panels
- Adjust Doors
- Install Side Panel
- Install Base Grille
- Install Odor Absorber (on some models)
- Complete Installation
- Water System Preparation
- REFRIGERATOR FEATURES
- Water and Ice Dispensers
- Ice Maker and Storage Bin
- Setting Liters and Ounces
- Measured Fill
- Water Filtration System
- Freezer Shelves
- PERFORMANCE DATA SHEET
- Performance Data Sheet
- SÉCURITÉ DU RÉFRIGÉRATEUR
- Sécurité du réfrigérateur
- MODÈLE
- Modèles
- ENTRETIEN ET RÉPARATION
- Nettoyage
- Remplacer le module à DEL
- Tablettes du réfrigérateur et balconnets de porte
- Mode Sabbat et entretien avant les vacances
- EXIGENCES D’INSTALLATION
- Outils et pièces
- Exigences d’emplacement
- Spécifications électriques
- Spécifications de l’alimentation en eau
- Rayon de basculement
- Dimensions du produit
- Dimensions pour l’ouverture des portes
- Dégagement des panneaux de porte de série Overlay et des armoires
- Panneaux personnalisés de série Overlay et ensembles de poignées
- Panneaux latéraux personnalisés Série Stainless
- INSTRUCTIONS D’INSTALLATION
- Déballage du réfrigérateur
- Raccordement à la canalisation d’eau
- Brancher le réfrigérateur
- Déplacement du réfrigérateur à son emplacement définitif
- Réglage de l’aplomb et alignement du réfrigérateur
- Installation des panneaux personnalisés de série Overlay
- Ajustement des portes
- Installation du panneau latéral
- Installation de la grille de la base
- Installer le filtre à odeurs (sur certains modèles)
- Achever l’installation
- Préparation du circuit d’eau
- CARACTÉRISTIQUES DU RÉFRIGÉRATEUR
- Distributeurs d’eau et de glaçons
- Machine à glaçons et bac d’entreposage
- Réglage en litres ou en onces
- Remplissage mesuré
- Système de filtration de l’eau
- Tablettes du congélateur
- FICHE DE DONNÉES DE PERFORMANCE
- Fiche de données de performance
20
Connect the Water Supply
Read all directions before you begin.
IMPORTANT:
� If you turn the refrigerator on before the water line is
connected, turn the ice maker OFF.
� Connect to potable water supply only.
Do not use with water that is microbiologically unsafe or of
unknown quality without adequate disinfection before or after the
system. Systems certified for cyst reduction may be used on
disinfected waters that may contain filterable cysts.
Connect to Water Line
Parts Needed
� Minimum 7 ft (2.13 m) flexible, codes-approved water supply
line.
Style 1 – Shutoff Valve Connection
NOTE: If your water line connection does not look like Style 1, see
"Style 2 — Copper Line Connection."
1. Unplug refrigerator or disconnect power supply.
IMPORTANT:
� There is not enough clearance to achieve a flush
installation if a water shutoff valve is located in the wall
behind the refrigerator. The water shutoff should be located
in the base cabinet on either side of the refrigerator.
� Before attaching the tubing to shutoff valve, flush the main
water supply line to remove particles and air in the water
line. Allow enough flow so that water becomes clear.
Flushing the water line may help avoid filters and/or water
valves from becoming clogged.
2. Connect the flexible, codes-approved water supply line to the
water shutoff valve by threading the provided nut onto the
shutoff valve as shown.
A. Bulb
B. Nut
C. Water tubing
3.
Place the end of the tubing into a bucket, and turn shutoff
valve ON.
4. Check for leaks. Tighten any nuts or connections (including
connections at the valve) that leak.
Style 2 — Copper Line Connection
NOTE: If there is a water supply line that meets the specifications
in "Water Supply Requirements," proceed to "Connecting to
Refrigerator." If not, use the following instructions to connect to the
household cold water supply.
1. Unplug refrigerator or disconnect power.
2. Turn OFF main water supply. Turn ON nearest faucet long
enough to clear line of water.
3. Locate a 1/2" to 1
1
/
4
" (1.3 cm to 3.18 cm) vertical cold water
pipe near the refrigerator.
IMPORTANT:
� Make sure it is a cold water pipe.
� Horizontal pipe will work, but drill on the top side of the
pipe, not the bottom. This will help keep water away from
the drill and keep normal sediment from collecting in the
valve.
4. Determine the length of copper tubing you need. Measure from
the connection on the refrigerator to the water pipe. Add 7 ft
(2.1 m) to allow for cleaning. Use 1/4" (6.35 mm) O.D. (outside
diameter) copper tubing. Be sure both ends of copper tubing
are cut square.
5. Using a cordless drill, drill a 1/4" (6.35 mm) hole in the cold
water pipe you have selected.
6.
Fasten the shutoff valve to the cold water pipe with the pipe
clamp. Be sure the outlet end is solidly in the 1/4" (6.35 mm)
drilled hole in the water pipe and that the washer is under the
pipe clamp. Tighten the packing nut. Tighten the pipe clamp
screws slowly and evenly so washer makes a watertight seal.
IMPORTANT: Before attaching the tubing to shutoff valve, flush the
main water supply line to remove particles and air in the water line.
Allow enough flow so that water becomes clear. Flushing the water line
may help avoid filters and/or water valves from becoming clogged.
7.
Slip the compression sleeve and compression nut on the
copper tubing as shown. Insert the end of the tubing into the
outlet end squarely as far as it will go. Screw compression nut
onto outlet end with adjustable wrench. Do not overtighten the
clamp or the sleeve. This will crush the copper tubing.
8. Turn off the shutoff valve on the water pipe. Coil the copper
tubing.
9. Connect the flexible, codes-approved water supply line to the
water shutoff valve by threading the provided nut onto the
shutoff valve.
10. Place the end of the tubing into a bucket, and turn shutoff
valve ON.
11. Check for leaks around the saddle valve. Tighten any nuts or
connections (including connections at the valve) that leak.
A. Cold water pipe
B. Pipe clamp
C. Copper or PEX
tubing
D. Compression nut
E. Compression sleeve
F. Shutoff valve
G. Packing nut