Alarm Probable cause Verification
Full tank
Bin
Machine is stopped
Thermostat failure
In the storage bin the ice cubes
do not touch the thermostat rod
Cycle probe.
Machine is stopped
Damaged cycle probe
Room temperature information
menu *****
High temperature
Machine is stopped
Lack of ventilation
Objects that block the machine
air inlet
Dirty ventilation filter
Dirty condenser
Short time
Machine is stopped
No Water incoming into the machine.
Water supply
Filter or water valve
No water arrive to nozzles
Pump does not work
Impulse tube or nozzle are loose
Long time
Machine is stopped
The compressor or the fan isn’t
working
Output 1 information menu,
signal during manufacturing
process.
Lack of ventilation
Low or no passage of
recommended air outlets