Installation Instruction
3
Location Requirements
IMPORTANT: Observe all governing codes and ordinances.
When installing cooktop, use minimum dimensions given.
n Use the countertop opening dimensions that are given
with these Installation Instructions. Given dimensions are
minimum clearances and provide 0" (0 cm) clearance.
n Grounded electrical supply is required. See the “Electrical
Requirements” section.
n If cabinet has drawers, drawers will need to be removed and
drawer fronts installed on front of cabinet.
n To eliminate the risk of burns or re by reaching over the
heated surface units, cabinet storage space located above
the surface units should be avoided. If cabinet storage is not
provided, the risk can be reduced by installing a range hood
or microwave hood combination that projects horizontally a
minimum of 5" (12.7 cm) beyond the bottom cabinets.
IMPORTANT: An undercounter built-in oven cannot be installed
under this product.
Product Dimensions
30" (76.2 cm) Cooktop – for standard and electric models
36" (91.4 cm) Cooktop – for standard and electric models
A. 22
1
/
16
" (56.0 cm) without stainless steel trim or
22
1
/
2
" (57.2 cm) or 23" (58.5 cm) with stainless
steel trim (depending on model)
B. Model/serial/rating/clearance plate location
C. 20
53
/
64
" (52.9 cm) screw head to screw head
A. 30
7
/
8
" (78.4 cm)
B. 12
7
/
16
" (31.6 cm)
C. 28
35
/
64
" (72.5 cm)
D. 14
29
/
64
" (36.7 cm)
E. 1
41
/
64
" (4.2 cm)
NOTE: 2" (5.1 cm) recommended
minimum cabinet to motor clearance
F. 17
29
/
32
" (45.5 cm)
G. 3
3
/
4
" (9.5 cm)
A. 20
53
/
64
" (52.9 cm) screw head to screw head
B. Model/serial/rating/clearance plate location
C. 22
1
/
16
" (56.0 cm) without stainless steel trim or
22
1
/
2
" (57.2 cm) or 23" (58.5 cm) with stainless
steel trim (depending on model)
A. 36
5
/
16
" (92.3 cm)
B. 11
13
/
16
" (30.0 cm)
C. 34
1
/
4
" (87.0 cm)
D. 14
29
/
64
" (36.7 cm)
E. 8" (20.3 cm)
NOTE: 2" (5.1 cm) recommended
minimum cabinet to motor clearance
F. 17
29
/
32
" (45.5 cm)
G. 3
3
/
4
" (9.5 cm)