Dimensions Guide

PRODUCT DIMENSIONS
Undercounter Dishwasher
PRODUCT MODEL NUMBERS
KDFE104D
KDFE304D
KDTE104D
KDTE204D
KDTE404D
Because Whirlpool Corporation policy includes a continuous commitment to improve
our products, we reserve the right to change materials and specifications without notice.
Dimensions are for planning purposes only. For complete details, see Installation
Instructions packed with product. Specifications subject to change without notice.
W10579129-D-KA
12/20/13
24¹⁄₂"
(62.2 cm)
B
23⁷⁄₈"
(60.6 cm)
27¹⁄₂"
(68.8 cm)
C
B. For panel ready models, dishwasher
depth is 24" (60 cm) not including the
³⁄₄" (1.9 cm) custom door panel.
C. For Pro Line handle, depth is
28" (70 cm).
®
³⁄₄"
(1.9 cm)
A
A. Insulation may be compressed
(not used on all models).
33¹⁄₂"
(85.1 cm)
min. with
wheels
removed
3¹⁄₂" - 4¹⁄₄"
(8.8 cm - 10.6 cm)
For 4" (10 cm) toe
kick, height of cabinet
opening is 34¹⁄₂" (86.3 cm).
3³⁄₄"
(9.4 cm)
21"
(53.3 cm)
30"
(76.2 cm)
Page 1 of 2
Electrical Requirements: 120-volt, 60 Hz, AC-only, 15- or
20 amp fused electrical supply. Copper wire only. A
time-delay fuse or circuit breaker and separate circuit is
recommended.
Water Supply Requirements: A hot water line with 20 to
120 psi (138 to 862 kPa) water pressure. Water
temperature must be 120°F (49°C) water at dishwasher.
Use ³⁄₈" O.D. copper tubing with compression fitting or
flexible braided supply line (¹⁄₂" minimum plastic tubing is
not recommended). Use a 90° elbow with ³⁄₄" N.P.T. external
pipe threads on one end. Do not solder within 6" (15.2 cm)
from water inlet valve.
Drain Requirements: A new drain hose is supplied with
your dishwasher. If this is not long enough, use a new drain
hose with a maximum length of 12 ft (3.7 m) (Part Number
3385556) that meets all current AHAM/IAPMO test
standards, is resistant to heat and detergent, and fits the 1"
(2.5 cm) drain connector of the dishwasher.
Make sure to connect the drain hose to waste tee or
disposer inlet above drain trap in house plumbing and 20"
(50.8 cm) minimum above the floor. It is recommended
that the drain hose either be
looped up and securely
fastened to the underside of
the counter, or be connected
to an air gap.
Make sure to use an air gap
if the drain hose is
connected to house
plumbing lower than 20"
(50.8 cm) above subfloor or
floor.
Use ¹⁄₂" (1.3 cm) minimum I.D. drain line fittings.
If required, the air gap should be installed in accordance
with the air gap installation instructions. When you connect
the air gap, a rubber hose (not provided) will be needed to
connect to the waste tee or disposer inlet.
air gap

Summary of content (2 pages)