Installation guide

4-Wire
Cable
from
Power
Supply
3-Wire
Cable
from
Power
Supply
IMPORTANT:
Use
the
4-wire
cable
from
power
supply
where
local
codes
do
not
permit
connecting
the
frame-ground
conductor
to
the
neutral
(white)
junction
box
wire.
A
B
G
C
H
D
|
F,
White
wires
G.
UL
listed
wire
connectors
H.
Black
wires
|.
UL
listed
or
CSA
approved
conduit
connector
A.
Cable
from
power
supply
B.
Red
wires
C.
Green
(or
bare)
ground
wires
D.
4-wire
flexible
cable
from
range
E.
Junction
box
1.
Disconnect
power.
2.
Remove
junction
box
cover
if
present.
3.
Connect
the
4-wire
flexible
cable
from
the
range
to
the
junction
box
using
a
UL
listed
or
CSA
approved
conduit
connector.
4.
Tighten
screws
on
conduit
connector
if
present.
5.
Connect
the
2
black
wires
together
using
the
UL
listed
wire
connectors.
6.
Connect
the
2
white
wires
together
using
the
UL
listed
wire
connectors.
7.
Connect
the
green
or
bare
ground
wire
from
the
range
cable
to
the
green
or
bare
grounded
wire
(in
the
junction
box)
using
the
UL
listed
wire
connectors.
8.
Install
junction
box
cover.
9.
Reconnect
power.
10
IMPORTANT:
Use
the
3-wire
cable
from
power
supply
where
local
codes
permit
connecting
the
frame-ground
conductor
to
the
neutral
(white)
junction
box
wire
(not
used
for
Canadian
installations).
a)
A.
Cable
from
power
supply
G.
4-wire
flexible
cable from
B.
Junction
box
range
C.
Red
wires
H.
Black
wires
D.
White
wire
(from
power
supply)
|
UL
listed
wire
connectors
E.
Green
(or
bare)
grounding
wires
J.
UL
listed
or
CSA.
(from
range)
approved
conduit
F.
White
wire
(from
range)
connector
1.
Disconnect
power.
Remove
junction
box
cover
if
present.
3.
Connect
the
4-wire
flexible
cable
from
the
range
to
the
junction
box
using
a
UL
listed
or
CSA
approved
conduit
connector.
4.
Tighten
screws
on
conduit
connector
if
present.
5.
Connect
the
2
black
wires
together
using
UL
listed
wire
connectors.
6.
Connect
the
2
red
wires
together
using
UL
listed
wire
connectors.
7.
Connect
the
green
(or
bare)
and
white
range
cable
wires
to
the
white
(neutral)
wire
in
the
junction
box
using
UL
listed
wire
connectors.
8.
Install
junction
box
cover.
9.
Reconnect
power.
nN
AWARNING
Excessive
Weight
Hazard
Use
two
or
more
people
to
move
and
install
range.
Failure
to
do
so
can
result
in
back
or
other
injury.
1.
Using
2
or
more
people,
move
range
close
to
cabinet
opening.
2.
Remove
cardboard
or
hardboard
from
under
range.
Move
range
into
it’s
final
location.
3.
Attach
the
backguard
or
island
trim
as
required
for
your
installation.
See
“Tools
and
Parts.”
Attachment
screws
are
included
in
the
literature
package.