Quick Start Guide

20
4. Open the oven door and remove the 2 screws on each side
of the range that hold the control console in place.
NOTE: Make sure to leave oven door open or the control
console will not rest in the side brackets properly once it
is detached.
5. Pull up on the control console, and let it drop forward into
the notched console brackets on each side.
6. Remove the round gasket from the valve stem.
7. Put a control knob onto the valve stem of the burner you
want to adjust.
8. Turn the control knob to LO and, using a butane extension
lighter, light the burner.
9. Remove the control knob.
10. Use a
1
/
8
" x 4
1
/
4
" flat-blade screwdriver to adjust the flame
height. Tighten screw to reduce flame height. Loosen screw
to increase flame height.
NOTE: When you are converting to LP gas, the screw
should be tightened down completely on the single output
valves. The dual output valve should not be adjusted.
11. When finished adjusting the flame height, put a control
knob back onto the valve stem and turn off the burner.
12. Remove the control knob.
13. Replace the round gasket.
14. Repeat steps 6 through 13 for any other burners that
need adjustment.
15. Lift up on the control console and set it back into place.
For a proper fit, the flange of the control console must
hook over the lip on the front of the range cooktop.
16. Check that the control console is flush with the top edge
of the range.
17. Replace the 2 screws on each side of the control console.
18. Replace the control knobs.
19. Replace burner grates.
20. Test the flame by turning the control from LO to HI, checking
the flame at each setting.
A
A. Control console bracket
A
B
A. Single flame burner adjustment screw (on right side of valve)
B. Dual flame burner adjustment screw (on left side of valve)
A
B
A. Control console flange
B. Front lip of range cooktop
A
A. Flush with range top