Installation guide

Cabinet
Dimensions
Cutout
Dimensions
A.
28%"
(73.4
cm)
maximum
on
30"
(76.2
cm)
models
34%s"
(87.8
cm)
maximum
on
36"
(91.4
cm)
models
B.
21%"
(53.7
cm)
maximum
on
both
30"
(76.2
cm)
and
36"
(91.4
cm)
models
C.
8'%2"
(21.8
cm)
on
30"
(76.2
cm)
models
15%6"
(39.2
cm)
on
36"
(91.4
cm)
models
A.
30"
(76.2
cm)
on
30"
(76.2
cm)
models
36"
(91.4
cm)
on
36"
(91.4
cm)
models
D.
Or%a"
(16.0
cm)
on
both
30"
(76.2
cm)
and
36"
(91.4
cm)
models
B.
Combustible
area
above
countertop
(shown
by
dashed
box
above)
E.2"
(5.1
cm)
minimum
space
to
front
edge
of
cooktop
C.
30"
(76.2
cm)
minimum
clearance
between
top
of
cooktop
platform
F.
Floor
exhaust
option
and
bottom
of
uncovered
wood
or
metal cabinet
(24"
[61
cm]
G.
62"
(15.6
cm)
for
6"
(15.2
cm)
vent
system
minimum
clearance
if
bottom
of
wood
or
metal
cabinet
is
covered
5%"
(13
cm)
for
5"
(12.7
cm)
vent
system
by
not
less
than
V4"
[0.6
cm]
flame
retardant
millboard
covered
with
H.
8'%2"
(21.8
cm)
on
30"
(76.2
cm)
models
not
less
than
No.
28
MSG
sheet
steel,
0.015"
[0.04
cm]
stainless
157/46"
(39.2
cm)
on
36"
(91.4
cm)
models
steel,
or
0.024"
[0.06
cm]
aluminum
or
0.020"
[0.05
cm]
copper)
:
1,
16"
(40.6
cm)
on
both
30"
(76.2
cm)
and
36"
(91.4
cm)
models
D.
13"
(33
cm)
recommended
upper
cabinet
depth
J.
Wall
exhaust
option
E.2"
6.1
cm)
F.
21%"
(73.4
cm)
G.
18"
(45.7
cm)
minimum
clearance
from
upper
cabinet
to
countertop
Venter
Gore
trorrenic
within
minimum
horizontal
clearances
to
cooktop
ver
WAG
Require
Mens
H.
Junction
box
or
outlet;
12"
(30.5
cm)
minimum
from
bottom
of
IMPORTANT:
This
cooktop
must
be
exhausted
outdoors.
countertop
. .
m
Donotterminate
the
vent
system
in
an attic
or
other
enclosed
|.
Junction
box
or
outlet;
10"
(25.4
cm) from
right-hand
side
of
cabinet
area.
J.
28%"
(73.4
cm)
on
30"
(76.2
cm)
models
ag
Useavent
cap.
34%6"
(87.8
cm)
on
36"
(91.4
cm)
models
; ;
K.
2%"
(6.4
cm)
minimum
distance
to
nearest
left
and
right
side
m
Vent
system
must
terminate
to
the
outside.
combustible
surface
above
cooktop
W
1
41
W W
L.
1%"
(3.8
cm)
minimum
clearance
between
back
wail
and
Use
only
a
6"
(15.2
cm)
diameter
round
or
34"
x
10
countertop
(8.3
x
25.4
cm)
rectangular
vent
except
as
follows:
For
electric
cooktops,
a
5"
(12.7
cm)
diameter
round
vent
may
be
NOTES:
After
making
the
countertop
cutout,
some
installations
used
for
venting
straight
out
the
back
of
the
cooktop
and
may
require
notching
down
the
base
cabinet
side
walls
to
clear
directly
through
the
wall
for
10
ft
(3.0
m)
or
less.
the
cooktop
base.
To
avoid
this
modification,
use
a
base
cabinet
with
sidewalls wider
than
the
cutout.
m=
Aminimum
side
clearance
of
6"
(15.2
cm)
is
recommended
m
Before
making
cutouts,
make
sure
there
is
proper
clearance
within
the
wall
or
floor
for
the
exhaust
vent.
between
side
of
cooktop
and
side
wall
for
maximum
m
Do
not
cut
a
joist
or
stud
unless
absolutely
necessary.
If
a
ventilation
performance.
joist
or
stud
must
be
cut,
then
a
supporting
frame
must
be
constructed.
ga
Aminimum
clearance
of
2"
(5.1
cm)
is
recommended
. ;
between
the
motor/blower
and
cabinet
for
proper
cooling.
A
m
The
size
of
the
vent
should
be
uniform.
6"
(15.2
cm)
clearance
is
recommended
for
servicing
access.
|
g
~The
vent
system
must
have
a
damper.
If
roof
or
wall
cap
has
a
damper,
do
not
use
damper
supplied
with
the
range
hood.
Use
vent
clamps
to
seal
all
joints
in
the
vent
system.
Use
caulking
to
seal
exterior
wall
or
roof
opening
around
the
cap.
m
Determine
which
venting
method
is
best
for
your
application.