Installation guide
I For all cooktop models with three-wire cable from the cooktop:
Where tocal codes Do Not permit connecting the frame-
ground conductor to the neutral (white) junction box
wire. (Used for Canadian installations):
4=wire cable from power supply
red wires _Junctiee box
Ungrounded
white wire
neutra_ j
Figure 1
twist-on
connector
bare or green
1oDisconnect wires
U,L,- or CSA- listed
power supp{yo 3-wire cable conduit connector
2oRemove the junction fromcooktop
box cover from the junction box inside the cabinet,
3oConnect the flexible, armored cable from the cooktop to the
junction box using a U=L=or CSAqisted conduit connector,
Tighten screws on conduit connector.
4, Connect the two black wires together; then connect the two red
wires together using twist-on connector. (See Figure 1.)
5, Connect the green or bare ground wire from the cooktop cable
to the grounded wire in the junction box or other grounded
connector using twist-on connector,
6oPut a twist-on connector on end of white wire. Do Not connect
bare ground wire to neutra8 (white) wire in junction box,
7. Replace the junction box cover,
Where Jocal codes permit connecting the frame-ground
conductor to the neutral (white) junction box wire. (Not
used for Canadian installations):
3=wire cable from power supply
Groundedneutra_Figure2 redwiL_ __nestor_--q_r'--,._/junctiontwist-onbox
white _ _ Mack wires
bare or J -"
green wire
3-wire cable _J _ U.L- or CSA- listed
1. Disconnect from cooktop _ conduit connector
power supply.
2. Remove the junction box cover from the junction box inside
the cabinet,
3. Connect the flexible, armored cable from the cooktop to the
junction box using a U,L- or CSAqisted conduit connector,
Tighten screws on conduit connector,
4. Connect the bare cooktop wire with the white wire; the two
red wires together; and the two black wires together using
twist-on connectors, (See Figure 2,)
5. Replace the junction box cover,
For aH cooktop models with four-wire cable from the cooktop. (These cooktops are manufactured with white
[neutron] power supply wire and a cabinet-connected bare ground wire factory-crimped together.):
Where tocaJ codes Do Not permit connecting the frame-
ground conductor to the neutraJ (white) junction box
wire: (Used for Canadian installations):
4-wire cable from power supply
red wires J junction box
_J
U n g re u n ded _ white wires
neutra_
Figure 3 _ \twist=on
cormector
green
wires
J '_Mack wires
1o Disconnect 4-wire cable
power supplyo from cookto \ U,L,- or CSA- listed
conduit coneector
2. Remove the junction
box cover from the junction box inside the cabinet,
3. Connect the flexible, armored cable from the cooktop to the
junction box using a U=L- or C=S=A=qistedconduit connector,
Tighten screws on conduit connector,
4. Connect the two black wires together; then connect the two red
wires together using twist-on connectors, (See Figure 3,)
5. Separate the factory-crimped bare and white cooktop cable wires,
6oConnect the two white wires together using twist-on connectors,
7. Connect the bare ground wire from the cooktop cable to the
grounded wire in the junction box or other grounded connector
using twist-on connector, (See Figure 3,)
Do Not connect bare ground wire to neutron (white) wire in
junction box.
8. Replace the junction box cover=
Where tocaJ codes permit connecting the frame-ground
conductor to the neutraJ (white) junction box wire. (Not
used for Canadian installations):
3-wire cable from
junction power supply
box
red
black
Figure 4
white
wire
white and
grounding oven cable
wires -- factory U,L,- or CSA-
crimped listed conduit
1. Disconnect 4-wire cable from cooktop connector
power supply.
2oRemove the junction
box cover from the junction box inside the cabinet,
3oConnect the flexible, armored cable from the cooktop to
the junction box using a U,L- or C,S,A,qisted conduit
connector, Tighten screws on conduit connector,
4, Connect the two black wires together; the two red
wires together; and the factory=crimped bare and
white cooktop cable wires to the white (neutral) wire
in the junction box using twist-on connectors, (See
Figure 4,)
5. Replace the junction box cover,