Installation guide

if codespermitandaseparateground
wireis used,it is recommendedthata
qualifiedelectriciandeterminethatthe
groundpathis adequate.
Do Not ground to a gas pipe.
Check with a qualified electrbian if you
are not sure cooktop is properly
grounded.
Do Not have a fuse in the neutral or
grounding circuit.
The down@aft cooktop must be
connected to the proper electrical voltage
and frequency as specified on the
model/serial rating plate. The model/serial
rating plate is located on the bottom of the
cooktop.
[] A four-wire or three-wire, singb-phase,
240-volt, 60-Hz, AC-only electrical
supply is required on a separate
30-ampere circuit, fused on both sides
of the line.
[] A time-delay fuse or circuit breaker is
recommended. The fuse size must not
exceed the circuit rating of the
appliance as specified on the
model/serial rating plate.
[] CONNECT WITH COPPER WIRE
ONLY.
[] Connected directly to the fused
disconnect (or circuit breaker box)
through flexible, armored or non °
metallic sheathed, copper cable (with
ground wire).
[] Flexible armored cable should connect
cooktop directly to the junction box.
[] Fuse both sides of the fine.
[] Locate the junction box to allow as
much slack as possible between the
junction box and cooktop so that the
downdraft eooktop can be moved if
servicing is ever necessary.
[] A twist=on connector and 1/2"
(12.7 mm) U.L o or CSA=listed conduit
connector must be provided at the
junction box.
The recommended minimum copper
wire size is No.-lO gauge. However,
wire sizes and connections must conform
to the requirements of the National
Electrical Code, ANSI/NFPA 70 -- latest
edition*, or CSA Standards C22.1-94,
Canadian Electrical Code, Part 1 and
22.2
No. 0-M91 - latest edition** and all local
codes and ordinances. Wire sizes and
connections must conform with the rating
of the cooktop.
Copiesofthe standardlistedmaybe obtainedfrom:
* National Fire Protection Association
Batterymarch Park
Quincy,Massachusetts02269
** CSA International
8501 East Pleasant Valley Road
CleveRand,Ohio 44131o5575
The wiring diagram is located on the
bottom of the cooktop.
Twist-on connector and 1/2" (12.7 ram)
U.L o or CSA-listed conduit connector are
not provided.
E Remove shipping materials and tape
from cooktop.
The blower is set to vent straight out
the back of the cooktop.
To vent to the left side, right side or down
through the bottom of the cabinet, add an
elbow to the blower assembly exhaust vent.
It may be easier to connect appliance
cable to junction box before inserting
cooktop into cutout. See "Electrical
connections," Pages 6-8.
[] front edge of downdraft cooktop is at least
lq/2" (38.1 ram) from front edge of
countertop and parallel to countertop.
[] rear edge of cooktop is at least 3/4"
(19.1 ram) from rear wall as recommended.
[] side edge of cooktop is at least 6 inches
(152 cm) from side wall.
m Connectvent system.See"Venting
requirements,"Pages4=5.Useduct tape to
sea!all joints.Vent must end witha wall or
roof cap outsidethe building.
This cooktop must be connected to a
grounded, metallb permanent wiring
system or a ground connector shoumd be
connected to the ground terminam or wire
bad on the cooktop.
This cooktop is manufactured with a frame
connected, green or bare ground wire. Connect
the cooktop cable to the junction box through
the 1/2" (1£7 mm) U.L.=or CSA-listed conduit
connector. Complete electrical connection
according to local codes and ordinances.
Make the electrical connection:
Excessive Weight Hazard
Use two or more peopte to move
and install cooktop.
Failure to do so can result in back
or other injury.
Lift entire cooktop up from cutout
when positioning cooktop in
countertop opening.
3m insert downdraft cooktop into cutout.
Check that:
[] cooktop is centered in cutout.
Electrical Shock Hazard
Turn power supply off before
connecting wires.
Use !O-gauge solid copper wire.
Electrically ground cooktop.
Failure to follow these
instructions can result in death,
fire, or etectricaJ shock.