Installation guide
36" (91.4 cm) Cooktop - for standard and electric models
Cabinet Dimensions
A. Model/serial rating/clearance plate location
B. 21" (53.4 cm) screw head to screw head
C. 22" (52.3 cm) without stainless steel trim or
2137/64'' (54.8 cm) with stainless steel trim
C
B
A =r
A. 35_%4'' (90.1 cm) with stainless steel trim
B. 35_%4" (89.9 cm) without stainless steel trim
C, 1 731/64 '' (43.8 cm)
D. 3_%_'' (9.6 cm)
E. 1813/32'' (46.8 cm)
F. 817/64 '' (20,9 cm)
G. 133/32" (33.3 cm)
H. 131/16'' (33.2 cm)
I.3431/64'' (87.6 cm) screw head to screw head
A. 30" (76.2 cm) on 30" (76.2 cm) models
36" (91.4 cm) on 36" (91.4 cm) models
B. Combustible area above countertop (shown by dashed box above)
C. 30" (76.2 cm) minimum clearance between top of cool(top platform
and bottom of uncovered wood or metal cabinet (24" [61 cm[
minimum clearance if bottom of wood or metal cabinet is covered
by not less than 1/4"[0.6 cm] flame retardant millboard covered with
not less than No. 28 MSG sheet steel, 0.015" [0.04 cm] stainless
steel, or 0.024" [0.06 cm] aluminum or 0.020" [0.05 cm] copper)
D. 13" (33 cm) recommended upper cabinet depth
E. 2"(5.1 cm)
F. 211/8'' (73.4 cm)
G. 18" (45. 7 cm) minimum clearance from upper cabinet to countertop
within minimum horizontal clearances to cool(top
H. Junction box or outlet; 12" (30.5 cm) minimum from bottom of
countertop
I. Junction box or outlet; 10" (25.4 cm) from right-hand side of
cabinet
J. 287/8'' (73.4 cm) on 30" (76.2 cm) models
349/18'' (87.8 cm) on 36" (91.4 cm) models
K. 2V2" (6.4 cm) minimum distance to nearest left and right side
combustible surface above coot(top
L. 1V2" (3.8 cm) minimum clearance between back wall and
countertop
NOTES: After making the countertop cutout, some installations
may require notching down the base cabinet side walls to clear
the cooktop base. To avoid this modification, use a base cabinet
with sidewalls wider than the cutout.
• A minimum side clearance of 6" (15.2 cm) is recommended
between side of cooktop and side wall for maximum
ventilation performance.
• A minimum clearance of 2" (5.1 cm) is recommended
between the motor/blower and cabinet for proper cooling. A
6" (15.2 cm) clearance is recommended for servicing access.