Installation guide

Direct wire method: Copper or Aluminum wire
Four=wire electrical Three-wire eUectrica[
connection: connection:
Electrical Shock Hazard
Disconnect power before servicing.
Use 8 gauge copper wire, or 6 gauge
aluminum wire.
Electrically ground range.
Failure to follow these instructions can
result in death, fire, or electrical shock.
This range may be connected directly to
the fuse disconnect or circuit breaker box;
or with a U.hdisted, 40 amp range power
supply cable. Depending on your
electrical supply, make the required
three-wire or four-wire connection.
1. Disconnect power.
2. Remove the knockout as needed for
conduit connection.
4,
S,
6,
Assemble a
U.L.-listed
conduit
connector in
opening.
Strip outer covering back 3 inches to
expose wires. Strip the insulation back
1 inch from the end of each wire.
Allow enough slack in the wire to
easily attach the wiring terminal
block,
Complete electrical connection
according to your type electrical
supply ("Four-wire electrical
connection" or "Three-wire electrical
connection").
Use this method for new installations,
mobile homes, recreational vehicles and
whenever four-wire installation is
required.
7, Remove the ground-link screw from
the range frame. Save the ground-link
screw and cup washer. Bend the
grounddink away from the range so
that it does not contact the range. See
Figure 4.
,, from range
grounddink screw---.._%
Figure 4
8_
Use this method only if local codes
permit connecting ground conductor to
neutral supply wire.
7, Loosen (do not remove) the hex
washer head screw and insert the
neutral (white) wire under the screw
damp at the bottom of the center
position terminal connector, insert the
other two wires dines 1 and 2) under
the other two screw clamps. Securely
tighten the hex washer head screws
to 90 in/Ibs minimum torque to make
proper electrical connection. See
Figure 6.
I silver-colored
hex washer
head screw screw
\
\
neutral wire
2
Connect the bare ground wire to the g U.Ldisted
range using the ground-link screw
connector
and cup washer.The ground wire line 1 and power
must be attached first and must not
contact any other terminal. See supply cable.
Figure 5. Figure 6
_ex2_acSr_ silver-colored
/terminal block
screw
, line 2
line 1 (white wire}
U.L listed
from power
supply cable connector
and power
supply cable
Figure 5
9. Loosen (do not remove) the hex
washer head screw and insert the
neutral (white) wire under the screw
clamp at the bottom of the center
position terminal connector, insert
the other two wires (lines 1 and 2)
under the other two screw clamps.
Securely tighten the hex washer head
screws to 90 in/Ibs minimum torque
to make proper electrical connection.
See Figure 5.
headscrew
insert wire under _'J<_
clampscrew
_ j--
IL_,_JI _ hexwasher
insert wire under _, /_ head screw
screw clamp
8, Tighten the locking ring of the
conduit connector,
9, Replace the terminal block cover.
10, Tighten the locking ring of the
conduit connector.
11. Replace the terminal block cover,