Installation Instructions
15
5.  Remove spring retainer from the cap by turning the spring 
retainer counterclockwise. Locate the “LP” and “NAT” 
position on the spring retainer. Turn over the spring retainer 
so the “LP” arrow is pointing toward the cap.
6.  Tighten the gas pressure regulator cap by using a large 
at-blade screwdriver, turning the regulator cap clockwise.
7.  Test the gas pressure regulator and gas supply line.
The regulator must be checked at a minimum 1" (2.5 cm) 
water column above the set pressure. The inlet pressure to 
the regulator should be as follows for operation and checking 
the regulator setting:
Propane Gas:
Minimum pressure: 11" (27.9 cm) WCP
Maximum pressure: 14" (35.6 cm) WCP
Gas Supply Pressure Testing
Gas supply pressure for testing regulator must be at least 1" 
(2.5 cm) water column pressure above the manifold pressure 
shown on the model/serial/rating plate.
Line pressure testing above 1/2 psi (3.5 kPa) gauge (14" 
[35.6 cm] WCP)
The range and its individual shut-off valve must be 
disconnected from the gas supply piping system during 
anypressure testing of that system at test pressures in 
excess of 1/2 psi (3.5 kPa).
Line pressure testing at 1/2 psi (3.5 kPa) gauge (14" 
[35.6 cm] WCP) or lower
The range must be isolated from the gas supply piping 
system by closing its individual manual shut-off valve during 
any pressure testing of the gas supply piping system at test 
pressures equal to or less than 1/2 psi (3.5 kPa).
To Convert Surface Burners from Natural Gas to 
Propane
1.  If the burner grates are installed, remove them.
2.  Remove burner cap.
3.  Remove the burner base by rst removing (2) T-20 screws.
Burner
A.  Burner cap
B. Screws
C. Burner base
4.  Apply masking tape to the end of a 7 mm nut driver to help 
hold the gas orice spud in the nut driver while changing it. 
Insert nut driver into the gas opening and press down onto 
the gas orice spud and remove by turning the gas orice 
spud counterclockwise and lifting out. Set gas orice spud 
aside.
5.  Replace with correct Propane gas orice spud. See the 
“Propane Gas Orice Spud/Hood Chart”.
Use the following chart to nd the exact orice spud 
placement.
Propane Gas Orice Spud/Hood Chart 
Burner 
Rating
Stamp Size Burner Style
4,000 BTUs 63 0.63 mm Small burner
12,000 BTUs 103 1.03 mm Medium burner
13,000 BTUs 99
50
0.99 mm
0.50 mm
Large burner – main
Larger burner – simmer
NOTE: Refer to serial tag for more information on burner ratings 
and locations.
Burner orice spud
6.  Place Natural gas orice in plastic parts bag for future use 
and keep with package containing literature.
NOTE: There may be extra orices in your kit.
7.  Replace the burner base and screws. Tighten screws only 
until burner is snug to cooktop, do not over-tighten.
8.  Replace burner cap.
9.  Repeat steps 2 through 8 for the remaining burners.
Adjusting Simmer Low Setting on Surface Burners 
for Propane
1.  Unplug range or disconnect power.
2.  Using the square bit screwdriver, remove the surface burner 
control knobs and bezels (Oven control knobs and griddle 
control knobs do not have to be removed).
LP
NAT
LP
NAT
LP
NAT
LP
NAT
A
B
C
DE
A.  Access cap
B.  Metal seal
C. Gas pressure regulator
D.  Spring retainer in NAT 
position.
E.  Spring retainer in LP 
position.
A
B
A.  Size stamp
B.  Fuel type stamp (L or N)
A
C
B