Owner's Manual

13
Complete Connection
1. Check that the gas pressure regulator shutoff valve is in the
“on” position.
A. Gas pressure regulator shut-off valve shown in the “on”
position
2. Open the manual shutoff valve in the gas supply line. The
valve is open when the handle is parallel to the gas pipe.
A. Closed valve
B. Open valve
3. Test all connections by brushing on an approved noncorrosive
leak-detection solution. If bubbles appear, a leak is indicated.
Correct any leak found.
4. Remove cooktop burner caps and bases from package
containing parts. Place the burner bases as indicated by the
following illustration for your model:
For Oval burner models:
A. Medium
(Semi Rapid)
B. Large
(Ultra Rapid)
C. Oval
D. Small (Auxiliary)
E. Large (Ultra Rapid)
For Round burner models:
A. Medium
(Semi Rapid)
B. Large
(Ultra Rapid)
C. Medium
(Semi Rapid)
D. Small (Auxiliary)
E. Large (Ultra Rapid)
5. Burner caps should be level when properly positioned. If
burner caps are not properly positioned, surface burners will
not light. Place burner grates over burners and caps.
A. Burner base
B. Burner cap
C. Burner grate