Installation guide
Installation
Clearances
IMPORTANT:
If
installing
a
range
hood
or
microwave
hood
combination
above
the
range,
follow
the
range
hood
or
microwave
hood
combination
installation
instructions
for
dimensional
clearances
above
the
cooktop
surface.
A.
30"
(76.2
cm)
on
30"
(76.2
cm)
models;
36"
(91.4. cm)
on
36"
(91.4
cm)
models
B.
Combustible
area
above
countertop
(shown
by
dashed
box
above)
C.
30"
(76.2
cm)
minimum
clearance
between
top
of
cooktop
platform
and
bottom
of
uncovered
wood
or
metal
cabinet
(24"
[61.0
cm]
minimum
clearance
if
bottom
of
wood
or
metal
cabinet
is
covered
by
not
less
than
14"
[0.6
cm]
flame
retardant
millboard
covered
with
not
less
than
No. 28
MSG
sheet
steel,
0.015"
[0.04
cm]
stainless
steel,
or
0.024"
[0.06
cm]
aluminum
or
0.020"
[0.05
cm]
copper).
If
installing
a
range
hood
see
NOTES.”
D.
13"
(33.0
cm)
recommended
upper
cabinet
depth
E.
116"
(2.8
cm)
F.
20"
(50.8
cm)
G.
18"
(45.7
cm)
minimum
clearance
from
upper
cabinet
to
countertop
within
minimum
horizontal
clearances
to
cooktop
H.
Grounded
outlet
-
Locate
within
24"
(61.0
cm)
of
right
rear
corner
of
cutout
1,29" (73.7
cm)
on
30"
(76.2
cm)
models;
354"
(89.5
cm)
on
36"
(91.4
cm)
models
J.
24"
(61.0
cm)
minimum
countertop
depth
is
required
K.2%"
(7.3
cm)
minimum
distance
to
rear
combustible
surface
L.
Gas
line
opening
-
Wall:
anywhere
5"
(12.7
cm)
below
underside
of
countertop.
Cabinet
floor:
anywhere
within
6"
(15.2
cm)
of
rear
wall
is
recommended
M.
8"
(20.3
cm)
minimum
distance
to
nearest
left
side
combustible
surface.**
N.
8"
(20.3
cm)
minimum
distance
to
nearest
right
side
combustible
surface.
**
30"
(76.2
cm)
Cooktop
Overall:
M
+
N
must
equal
48"
(122.0
cm)
minimum
+
29"
(73.7
cm)
cutout
for
cooktop
or
77"
(195.6
cm)
36"
(91.4
cm)
Cooktop
Overall:
M
+
N
must
equal
48"
(122.0
cm)
minimum
+
35%"
(89.5
cm)
cutout
for
cooktop
or
83%"
(211.5
cm)
“M
+N
combined
must
be
at
least
48"
(122.0
cm)
minimum
overall
Example
1:
M
=
8"
(20.3
cm)
left
side
+
N
=
40"
(101.6
cm)
right
side
=
48"
(122.0
cm)
Example
2:
M
=
24"
(61.0
cm)
left
side
+
N
=
24"
(61.0
cm)
right
side
=
48"
(122.0
cm)
NOTES:
After
making
the
countertop
cutout,
some
installations
may
require
notching
down
the
base
cabinet
side
walls
to
clear
the
cooktop
base.
To
avoid
this
modification,
use
a
base
cabinet
with
sidewalls wider
than
the
cutout.
lf
cabinet
has
a
drawer,
a
4”
(10.2
cm)
depth
clearance
from
the
countertop
to
the
top
of
the
drawer
(or
other
obstruction)
in
base
cabinet
is
required.
The
drawer
depth
may
need
to
be
shortened
to
avoid
interfering
with
the
regulator.
Electrical
Requireme
Dia
Breast
Sona?
0
AWARNING
°
Electrical
Shock
Hazard
Plug
into
a
grounded
3
prong
outlet.
Do
not
remove
ground
prong.
Do
not
use
an
adapter.
Do
not
use
an
extension
cord.
Failure
to
follow
these
instructions
can
result
in
death,
fire,
or
electrical
shock.
IMPORTANT:
The
cooktop
must
be
electrically
grounded
in
accordance
with
local
codes
and
ordinances,
or
in
the
absence
of
local
codes,
with
the
National
Electrical
Code,
ANSI/NFPA
70
or
Canadian
Electrical
Code,
CSA
C22.1.
If
codes
permit
and
a
separate
ground
wire
is
used,
it
is
recommended
that
a
qualified
electrical
installer
determine
that
the
ground
path
is
adequate.
A
copy
of
the
above
code
standards
can
be
obtained
from:
National
Fire
Protection
Association
1
Batterymarch
Park
Quincy,
MA
02169-7471
CSA
International
8501
East
Pleasant
Valley
Road
Cleveland,
Ohio
44131-5575
mw
A120
volt,
60
Hz,
AC
only,
15-amp,
fused
electrical
circuit
is
required.
A
time-delay
fuse
or
circuit
breaker
is
also
recommended.
It
is
recommended
that
a
separate
circuit
serving
only
this
cooktop
be
provided.
mg
Electronic
ignition
systems
operate
within
wide
voltage
limits,
but
proper
grounding
and
polarity
are
necessary.
Check
that
the
outlet
provides
120-volt
power
and
is
correctly
grounded.
m_
The
Tech
Sheet
provided
is
located
inside
the
cooktop
on
the
left
wall
of
the
cooktop
base.