Installation Instruction
Table Of Contents

16
Natural Gas Conversion
1. Turn the manual shut-off valve to the closed position.
2. Unplug cooktop or disconnect power.
To Convert Gas Pressure Regulator
1. Remove the access cap by using a wrench, turning the
access cap counterclockwise.
2. Remove spring retainer from the cap by pushing against the
at side of the spring retainer. Look at the spring retainer to
locate the “LP” or “NAT” position. Turn over the spring
retainer so the “NAT” is showing on the bottom. Snap the
spring retainer back into the cap. Reinstall the cap onto the
regulator.
3. Test the gas pressure regulator and gas supply line.
The regulator must be checked at a minimum 2.5 cm water
column above the set pressure. The inlet pressure tothe
regulator should be as follows for operation and checking
the regulator setting:
Propane Gas:
Minimum pressure: 15.2 cm WCP
Maximum pressure: 35.6 cm WCP
Gas Supply Pressure Testing
Gas supply pressure for testing regulator must be at least
2.5 cm water column pressure above the manifold pressure
shown on the model/serial/rating plate.
Line pressure testing above 1/2 psi (3.5 kPa) gauge
(35.6cm WCP)
The cooktop and its individual shut-off valve must be
disconnected from the gas supply piping system during
anypressure testing of that system at test pressures in
excess of 1/2 psi (3.5 kPa).
Line pressure testing at 1/2 psi (3.5 kPa) gauge
(35.6cmWCP) or lower
The cooktop must be isolated from the gas supply piping
system by closing its individual manual shut-off valve during
any pressure testing of the gas supply piping system at test
pressures equal to or less than 1/2 psi (3.5 kPa).
To Convert Surface Burners
1. If installed, remove the burner grates.
2. Remove burner cap.
3. Remove the burner base.
A
B
Large Dual Burner
A. Burner cap
B. Burner base
A
B
C
Medium Burner
A. Burner cap
B. Burner base
C. Choke (for use with medium
burner, Propane gas only)
A
B
Small Burner
A. Burner cap
B. Burner base
4. Apply masking tape to the end of a 7 mm nut driver to help
hold the gas orice spud in the nut driver while changing it.
Insert nut driver into gas opening and press down onto the
gas orice spud and remove by turning the gas orice spud
counterclockwise and lifting out. Set gas orice spud aside.
5. Replace with correct Natural gas orice spud. See the
“Natural Gas Orice Spud/Hood Chart.”
Use the following chart to nd the exact orice spud
placement.
Remove choke from medium burner base.
Natural Gas Orice Spud/Hood Chart
Burner
Rating
Color Size Burner Style
5,000 BTUs NG 5k
Small
burner
bag
1.01 mm Small burners
15,000 BTUs No color 1.75 mm Medium burners
20,000 BTUs Blue/
Yellow
Black
0.10 mm
0.52 mm
Large burner - main
Large burner - simmer
14,500 BTU Black 1.18 mm Grill burner
(onsomemodels)
Burner orice spud Grill orice hood
A
A
A. Size stamp or color A. Size stamp
6. Place Propane gas orice spuds in plastic parts bag for
future use and keep with package containing literature.
NOTE: There may be extra orices in your kit.
7. Replace the burner base.
A
B
C
A. To cooktop
B. Shut-off valve (closed position)
C. Gas supply line
A
B
CDE
A. Access cap
B. Gasket
C. Gas pressure regulator
D. NAT position
E. LP position