Install Optional Backguard
48" (121.9 cm) models and all models with a grill may require
a backguard. See “Cabinet Dimensions” in the “Location
Requirements” section for installation requirements. See
the“Tools and Parts” section for information on ordering.
Remove island trim and attach backguard using six screws;
insertthree from the front and three from the back (9" [22.9 cm]
backguard shown).
Make Gas Connection
To Assemble Pressure Regulator:
1. Using two or more people, stand the cooktop on its side
orback.
2. Connect the exible stainless steel connector to the pressure
regulator using a 1/2" (13 mm) male pipe thread adapter.
A combination of pipe ttings must be used to connect the
cooktop to the existing gas line. The following shows a
typical connection. Your connection may be different,
according to the supply line type, size, and location.
3. Install the pressure regulator with the arrow pointing up
toward the bottom of the cooktop burner base and in a
position where you can reach the regulator cap.
IMPORTANT: All connections must be wrench-tightened.
Donot make connections to the gas regulator too tight.
Making the connections too tight may crack the regulator
and cause a gas leak. Do not allow the regulator to turn on
the pipe when tightening ttings.
Use only pipe-joint compound made for use with Natural
andPropane gas. Do not use TEFLON
®
tape.
You will need to determine the ttings required depending
onyour installation.
4. Place cooktop into the countertop cutout.
NOTE: Check that the front edge of the cooktop is parallel
tothe front edge of the countertop. If repositioning
is needed, lift entire cooktop up from cutout to avoid
scratching the countertop.
Typical exible connection
1. Apply pipe-joint compound made for use with Propane gas
to the smaller thread ends of the exible connector adapters
(see Band F in the following illustration).
2. Attach one adapter to the gas pressure regulator and
the other adapter to the gas shut-off valve. Tighten both
adapters.
3. Use a 15/16" (24 mm) combination wrench and channel lock
pliers to attach the exible connector to the adapters.
Checkthat connector is not kinked.
WARNING
Explosion Hazard
Use a new CSA International approved gas supply line.
Install a shut-off valve.
Securely tighten all gas connections.
If connected to propane, have a qualified person make
sure gas pressure does not exceed 14" (36 cm) water
column.
Examples of a qualified person include:
licensed heating personnel,
authorized gas company personnel, and
authorized service personnel.
Failure to do so can result in death, explosion, or fire.
B
C
A. Gas pressure regulator
B. Regulator - Must be installed with arrow pointing up
to cooktop bottom
C. Adapter - Must have 1/2" (13 mm) male pipe thread
D. CSA approved exible stainless steel gas supply line
A
B
C
D
E
F
G
H
A. Gas pressure regulator
B. Use pipe-joint compound.
C. Adapter - must have 1/2"
(13 mm) male pipe thread
D. Flexible connector
E. Adapter
F. Use pipe-joint compound.
G. 1/2" (13 mm) or 3/4"
(19mm) gas pipe
H. Manual gas shut-off valve
®