Installation guide

3.
Use a 1%6"combination wrench and channel lock pliers to
attach the flexible connector to the adapters. Check that
connector is not kinked.
A B C
/ D
E
H G F
A. Gas pressure regulator
B. Use pipe-joint compound
C. Adapter (must have Y2"male
pipe thread)
D. Flexible connector
E. Manual gas shutoff valve
R _2" or 3/4"gas pipe
G. Use pipe-joint compound
H. Adapter
Complete Connection
1. Check that the gas pressure regulator shutoff valve is in the
"on" position.
Electrical Shock Hazard
Pmuginto a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.
Failure to follow these instructions can resumt in death,
fire, or eJectdcam shock.
5. Plug into a grounded 3 prong outlet.
2.
3.
4.
A. Gas pressure regulator shutoff valve
Open the manual shutoff valve in the gas supply line. The
valve is open when the handle is parallel to the gas pipe.
A. Closed valve
B. Open valve
Test all connections by brushing on an approved
noncorrosive leak-detection solution. Bubbles will show a
leak. Correct any leak found.
Remove cooktop burner caps and grates from parts
package. Align notches in burner caps with pins in burner
base. Burner caps should be level when properly positioned.
If burner caps are not properly positioned, surface burners
will not light. Place burner grates over burners and caps.
Initial lighting and gas flame adjustments
Cooktop and oven burners use electronic igniters in place of
standing pilots. When the cooktop control knob is turned to the
"LITE" position, the system creates a spark to light the burner.
This sparking continues, as long as the control knob is turned to
"LITE."
When the oven control is turned to the desired setting, sparking
occurs and ignites the gas.
Check Operation of Cooktop Burners
Standard Surface Burners
Push in and turn each control knob to the "LITE" position.
The flame should light within 4 seconds. The first time a burner is
lighted it may take longer that 4 seconds to light because of air in
the gas line.
TripleTier TM Flame Burner
To start simmer burner:
Push in and turn control knob to "LITE."
The flame should light within 4 seconds. The first time a burner is
lighted it may take longer that 4 seconds to light because of air in
the gas line.
To start power burner:
Push in and turn control knob to "POWER BURNER HIGH."
The flame should light within 4 seconds. The first time a burner is
lighted it may take longer that 4 seconds to light because of air in
the gas line.
If burners do not light properly:
Turn cooktop control knob to the "OFF" position.
Check that the range is plugged in and the circuit breaker has
not tripped or the fuse blown.
Check that the gas shutoff valves are set to the "open"
position.
Check that burner caps are properly positioned on burner
bases.
Repeat start-up. If a burner does not light at this point,
contact your dealer or authorized service company for
assistance.
10