Instruction for Use

Category II2E+H3+
Electric Power: 230 V ~ 50 Hz
If a hood is to be installed above the hob, refer to the hood
installation instructions to ensure the hood is installed at the
correct minimum height above the hob.
Hood and cabinetry clearances (mm)
Injectors table
6
Type of gas used Type of
burner
Injector
label
Control
primary air
(X) (mm)
Nominal
heat flow
kW
Nominal
consumption
Reduced heat flow kW
Gas pressure (mbar)
BE FR min. nom. max.
NATURAL GAS
(Methane) G20
wok
semi-fast
auxiliary
145
95
78
11
-
-
4,20
1,65
1,00
400 l/h
157 l/h
95 l/h
1,40
0,45
0,35
1,40
0,35
0,30
17 20 25
LIQUID
PETROLEUM GAS
(Butane) G30
wok
semi-fast
auxiliary
100
65
50
11
-
-
4,20
1,65
1,00
305 g/h
120 g/h
73 g/h
1,40
0,35
0,30
1,40
0,35
0,30
20 28-30 35
LIQUID PETROLEUM
GAS (Propane) G31
wok
semi-fast
auxiliary
100
65
50
11
-
-
4,20
1,65
1,00
300 g/h
118 g/h
71 g/h
1,40
0,35
0,30
1,40
0,40
0,30
25 37 45
Type of gas used Configuration model Nominal heat flow kW Overall nominal
consumption
Required air (m
3
) for
the combustion 1 m
3
of
gas
G20 20 mbar 4 burners 8,50 809 l/h 9,52
G30 28-30 mbar 4 burners 8,50 618 g/h 30,94
G31 37 mbar 4 burners 8,50 607 g/h 23,80