Instruction for Use

The minimum flow level is regulated using the tap at the lowest
position (small flame) .
There is no need to regulate the primary air in the burners.
To ensure the minimum level is properly regulated, remove the
control knob and adjust the screws on the tap as follows:
1. Tighten to decrease the height of the flame 1 (-)
2. Loosen to increase the height of the flame (+);
3. With the burners on, turn the control knobs from the maximum
to the minimum position to check the stability of the
flame.
Once you have finished regulating the level, close the seals again
using sealing wax.
12
To replace the injectors in the special burner:
1. Remove the burner ring (C), the screws (B) holding the cover cap
in place (A) and the cap itself.
2. Unscrew the inner injector (D) and the outer injector (E) using a
7 mm hex key.
3. Replace the injectors.
4. Refit the cover cap, screws and burner ring.
Note: Make sure that:
1. The burner ring (C) is seated correctly on the burner following
replacement.
A
C
B
D E
Regulating the minimum flow level of the gas taps
Replacing the injectors in the wok burner