Instruction for Use

12
T
o replace the injectors in special burner it is neces-
sary to:
1. Remove spreader (C), the screws (B) holding the
cover cap (A) and the cap itself.
2. Unscrew the inner injector (D) and the outer
injector (E) with a box spanner 7.
3. Replace the injectors.
4. Put back the cover cap, screws and spreader.
Note: make sure that:
1. After replacement the spreader (C) is inserted
correctly on the burner.
Injectors replacement in the wok burner
Regulating the minimum flow level must be done with the tap at the
lowest position (small flame) .
There is no need to regulate the primary air in the burners.
To ensure the minimum level is properly regulated, remove the control
knob and adjust the screws found on the tap as follows:
1. tighten to reduce the height of the flame 1 (-)
2. slacken to increase the height of the flame (+);
3. With the burners on, rotate the buttons from the maximum to
the minimum position to check the stability of the flame.
.
Regulating the minimum flow level of the gas taps
A
C
B
E
D