Instruction for Use

11
WARNING
- Disconnect the appliance from the power supply.
- Installation must be carried out by a qualified electrician who is fully aware of current safety
and installation regulations.
- The manufacturer cannot be held responsible for injury to persons or animals and for damage
to property resulting from failure to observe the regulations provided in this section.
- The power supply cable must be long enough to allow the hob to be removed from the
worktop.
- Make sure the voltage specified on the appliance’s rating plate is the same as that of the
domestic electricity supply.
- Do not use extension leads.
Connecting to the terminal board
Use an H05RR-F cable as indicated in the table below for the electrical wiring.
Connect the yellow/green earth wire to the terminal with the symbol.
This wire must be longer than the other wires.
1. Remove the terminal block cover (A) by undoing the screw and inserting the cover in the terminal
block hinge (B).
2. Strip approx. 70 mm of sheathing from the power supply cable.
3. Strip approx. 10 mm of sheathing from the wires. Insert the power supply cable into the cable clamp
and connect the wires to the terminal board as shown in the diagram next to the terminal board.
4. Secure the power supply cable with the cable clamp.
5. Close the cover (C) and screw it on the terminal block using the screw you removed before - point
(1).
Every time the hob is connected to the mains, it will carry out an automatic check which takes several
seconds.
If the hob already has a power supply cable, follow the instructions accompanying the cable. Connect
the appliance to the mains electricity supply using a multi-pole disconnector with a minimum contact
gap of 3 mm.
Electrical wiring
CBA
230 V
230 V
230 V
230 V
230 V
230 V
230 V
230 V
230 V
230 V
230 V
Wires Quantity x size
220-240 V ~ +
3 x 4 mm
2
220-240 V 3 ~ +
5 x 1.5 mm
2
380-415 V 3N ~ +
5 x 1.5 mm
2
380-415 ~ +
4 x 1.5 mm
2
380-415 V 3N ~ 220-240 V ~ 220-240 V ~ (AU and UK)
380-415 V 2N ~ 220-240 V 3 ~
(Belgium only)
380-415 V 2N ~
(NL only)