Hood and cabinetry clearances (mm)
If a hood is to be installed above the hob, refer to the hood installation instructions to ensure the correct
height above the hob.
Note: If the distance “A” between
the wall cupboards in the kitchen
is between 600mm and 730mm,
the height “B” must be at least
530mm. If the distance “A”
between the wall cupboards is
greater than the width of the hob,
the height “B” must be at least
400 mm.
N.B. For the semi-ush mount version
the 1.5 mm milling is not necessary.
1100
+1
0
365
+1
0
R 12
1120
384
74
Injectors table
Category II2L3B/P
Type of gas used
Type of
burner
Injector
marketing
Nominal heat
ow kW
Rated
consumption
Reduced heat
capacity kW
Gas pressure mbar
min. nom. max.
NATURAL GAS
(Methane) G25
2 ring
102C+102C
(outer)
71 (inner)
4.00
0.80
443 l/h
89 l/h
1.50
0.30
20 25 30
rapid 130 3.00 332 l/h 0.70
semi-rapid 100 1.75 194 l/h 0.40
auxiliary 78 1.00 111 l/h 0.30
LIQUEFIED GAS
(Butane) G30
(Propane) G31
2 ring
80+80 (outer)
46(inner)
4.00
0.80
436 g/h
58 g/h
1.50
0.30
25 30 35
rapid 85 3.00 218 g/h 0.70
semi-rapid 66 1.75 127 g/h 0.40
auxiliary 50 1.00 73 g/h 0.30
Type of gas used
Model conguration
5 burners 2C 4.8kW
Rated thermal ow
rate kW
Total rated
consumption
Air required (m
3
) for
burning1 m
3
of gas
G25 20 mbar 2C-1R-1SR -1AUX 9.75 1080 l/h 8.187
G30/G31 30 mbar 2C-1R-1SR -1AUX 9.75 696 l/h 30.94
Electric supply:220-240 V ~ 50/60 Hz 0,6W