User guide

14
If you are using a dierent kind of gas from the one
indicated on the serial no. plate and the orange
label on the back of the hob, you must replace the
injectors; in the case of the Wok burner, adjust the
primary air (see Injector table on page 11).
The orange label should be removed and kept
together with the manual.
Use pressure regulators suitable for the gas
pressures indicated on page 11.
In order to replace the injectors, contact the
Customer Care Centre on 00800-3810-4026,
or a qualied electrician.
Injectors not supplied as standard should be
requested from the Customer Care Centre on
00800-3810-4026.
Regulate the minimum levels of the taps.
Note: with liquid petroleum gas ( G30/G31) the
bypass screw must be screwed in fully. If you
then experiance diculty in turning the control
knob, contact our After sales Service though
our Customer Care Centre on 00800-3810-4026,
who will arrange for a replacement after
ascertaining that the tap is damaged.
Adaption to a dierent type of gas supply
Replacing the injectors
Note: Refer to the table on page 11 to ensure the correct type
of injector is to be tted.
Traditional burners (T)
1. Remove the cap (A).
2. Remove the spreader (B).
3. Unscrew the injector (C) with a box spanner 7.
4. Replace the injector with the one for the new gas.
5. Put back burners and pan supports.
Note: Before installing the hob, please remember to stick the
gas calibtration label, provided with the replacement
injectors over the gas information on the underside of the
hob.
A
B
C