User guide

15
Injectors replacement in the wok burner
To replace the injectors in special burner it is necessary to:
1. Remove spreader (C), the screws (B) holding the cover cap (A) and
the cap itself.
2. Unscrew the inner injector (D) with a box spanner 7 and the outer
injectors (E) with a wrench 7.
3. Replace the injectors.
4. Put back the cover cap, screws and spreader.
Note: make sure that after replacement the spreader (C) is inserted
correctly on the burner.
Regulating the minimum ow level of the gas taps
Regulating the minimum ow level must be done with the tap
at the lowest position (small ame)
.
There is no need to regulate the primary air in the burners.
To ensure the minimum level is properly regulated, remove the
control knob and adjust the screws found on the tap as follows:
1. Tighten to reduce the height of the ame 1 (-)
2. Unscrew to increase the height of the ame (+);
3. With the burners on, rotate the buttons from the maximum
to the minimum position to check the stability of the
ame.
Once you have nished regulating, close up the seals again
using sealing wax.
A
C
B
E
D