User's Manual

6-5
DIAGNOSTIC FLOW CHART FOR
ICE MAKER CONTROL BOARD #6100499
Freeze Mode begins
(See page 6-8)
Service Mode begins
(See page 6-11)
Harvest Mode begins
(See page 6-9)
Idle Mode begins
(See page 6-7)
Flush Mode begins
(See page 6-6)
When time, or
temperature is
satisfied go this
direction
Idle Mode ends
when the bi n i s
not full
When "Clean" has ended
and "Power On" is
selected go this direction
When Harvest ends
go this direction i f
the bin is not full
OVERVIEW
The unit is first turned
on, (“On” is pressed)
Clean may be selected
at anytime. When
selected go this direction
5 minute Flush
Mode ends
Before using this chart, confirm that you have electronic control board #6100499.
Look for the part number on the control, or use the following procedure:
1. Disconnect the bin thermistor.
2. Place the unit into the Clean mode.
3. If the Clean LED flashes 2 times, it is the new control. The old control will not
flash the LED.
Clean Mode begins
(See page 6-11)
When Harvest ends
go this direction if
the bin is full