Installation Instructions
2
INSTALLATION INSTRUCTIONS
Tools and Parts
Tools Needed
Gather the required tools and parts before starting installation.
Read and follow the instructions provided with any tools listed
here.
■ Measuring tape ■ Drill
■ Pencil ■ 7/64" drill bit
■ Phillips screwdriver
Parts Supplied (not shown to scale)
Location Requirements
The microwave oven may be installed over a built-in oven. If
installing over a built-in oven, make sure there is a minimum of
3
15
⁄
16
" (10 cm) between the top of the lower oven cutout and the
microwave oven cutout oor.
The microwave oven may also be installed in a cabinet by itself
(without a built-in oven below). For best usability, we recommend
a minimum distance of 36
1
/
16
" (91.6 cm) from the oor to the
cutout oor.
Make sure the surrounding cabinetry has clearance to open and
close freely. Allow a clearance of at least 2" (5.1 cm) below the
cutout oor (3
15
⁄
16
" [10 cm] for installation above a built-in oven),
and a clearance of at least 2" (5.1 cm) above the cutout opening.
Required Cutout Dimensions-1•6 cuft•
For minimum depth requirements, see chart
Required Cutout Dimensions-2•2 cuft•
For minimum depth requirements, see chart
1.6 cuft.
Receptacle Location Minimum Depth
Within recommended
region
20" (50.8 cm) with ush receptacle;
23" (58.4 cm) with non-ush
receptacle
Outside recommended
region
23" (58.4 cm) with ush receptacle;
26" (66.0 cm) with non-ush
receptacle
2.2 cuft.
Receptacle Location Minimum Depth
Within recommended
region
22
3
⁄
4
" (57.8 cm) with ush receptacle;
26
3
⁄
4
" (67.9 cm) with non-ush
receptacle
Outside recommended
region
26
3
⁄
4
" (67.9 cm) with ush receptacle;
30
3
⁄
4
" (78.1 cm) with non-ush
receptacle
Rails (2) Bottom duct Trim kit frame
19# screw M4*10
(4 + 2 extra)
93# screw ST3*25
(4 + 2 extra)
A. Upper cabinet
B. Microwave oven
cutout
C. Lower oven cutout
D. Lower cabinets
E. Floor
3
15
/
16
"
(10 cm)
B
B
D
(91.6 cm)
C
36 "
1
/
16
2"
(5.1 cm)
2"
(5.1 cm)
2"
(5.1 cm)
E
A
A
(2.14 cm)
B
C
D
17
1
7
1
1
/
/
8
8
"
"
(43.5 cm)
(43.5 cm)
23
1
/
8
"
(58.7 cm)
(2.14 cm)
6"
(15.2 cm)
3
15
/
16
"
(10 cm)
13/16"
13/16"
minimum
maximum
A
(2.14 cm)
B
C
D
1
7
3
/
16
" (43.7 cm)
25
1
/2
"
(64.8 cm)
(2.14 cm)
6"
(15.2 cm)
3
15
/
16
"
(10 cm)
13/16"
13/16"
minimum
maximum
1
7
1
/
8
"
(43.5 cm)
A. Trim kit frame overhang
B. Cutout for lower oven
C. Recommended region for receptacle
location (no less than 6" [15.2 cm] to
the right of cutout centerline)
D. Cutout centerline
123# screw ST4*16
(7 + 3 extra)