Installation Instructions

2
INSTALLATION INSTRUCTIONS
Tools and Parts
Tools Needed
Gather the required tools and parts before starting installation.
Read and follow the instructions provided with any tools listed
here.
Measuring tape Drill
Pencil 7/64" drill bit
Phillips screwdriver
Parts Supplied (not shown to scale)
Location Requirements
The microwave oven may be installed over a built-in oven. If
installing over a built-in oven, make sure there is a minimum of
3
15
16
" (10 cm) between the top of the lower oven cutout and the
microwave oven cutout oor.
The microwave oven may also be installed in a cabinet by itself
(without a built-in oven below). For best usability, we recommend
a minimum distance of 36
1
/
16
" (91.6 cm) from the oor to the
cutout oor.
Make sure the surrounding cabinetry has clearance to open and
close freely. Allow a clearance of at least 2" (5.1 cm) below the
cutout oor (3
15
16
" [10 cm] for installation above a built-in oven),
and a clearance of at least 2" (5.1 cm) above the cutout opening.
Required Cutout Dimensions-16 cuft
For minimum depth requirements, see chart
Required Cutout Dimensions-22 cuft
For minimum depth requirements, see chart
1.6 cuft.
Receptacle Location Minimum Depth
Within recommended
region
20" (50.8 cm) with ush receptacle;
23" (58.4 cm) with non-ush
receptacle
Outside recommended
region
23" (58.4 cm) with ush receptacle;
26" (66.0 cm) with non-ush
receptacle
2.2 cuft.
Receptacle Location Minimum Depth
Within recommended
region
22
3
4
" (57.8 cm) with ush receptacle;
26
3
4
" (67.9 cm) with non-ush
receptacle
Outside recommended
region
26
3
4
" (67.9 cm) with ush receptacle;
30
3
4
" (78.1 cm) with non-ush
receptacle
Rails (2) Bottom duct Trim kit frame
19# screw M4*10
(4 + 2 extra)
93# screw ST3*25
(4 + 2 extra)
A. Upper cabinet
B. Microwave oven
cutout
C. Lower oven cutout
D. Lower cabinets
E. Floor
3
15
/
16
"
(10 cm)
B
B
D
(91.6 cm)
C
36 "
1
/
16
2"
(5.1 cm)
2"
(5.1 cm)
2"
(5.1 cm)
E
A
A
(2.14 cm)
B
C
D
17
1
7
1
1
/
/
8
8
"
"
(43.5 cm)
(43.5 cm)
23
1
/
8
"
(58.7 cm)
(2.14 cm)
6"
(15.2 cm)
3
15
/
16
"
(10 cm)
13/16"
13/16"
minimum
maximum
A
(2.14 cm)
B
C
D
1
7
3
/
16
" (43.7 cm)
25
1
/2
"
(64.8 cm)
(2.14 cm)
6"
(15.2 cm)
3
15
/
16
"
(10 cm)
13/16"
13/16"
minimum
maximum
1
7
1
/
8
"
(43.5 cm)
A. Trim kit frame overhang
B. Cutout for lower oven
C. Recommended region for receptacle
location (no less than 6" [15.2 cm] to
the right of cutout centerline)
D. Cutout centerline
123# screw ST4*16
(7 + 3 extra)