Installation Dimensions
NOTE: The grounded 3 prong outlet must be inside the upper
cabinet. See the “Electrical Requirements” section.
*Overall depth of product will vary slightly depending on
door design.
A. 2" x 4" wall stud
B. Grounded 3 prong outlet
12" (30.5 cm) min.
14" (35.6 cm) max.
30"
(76.2 cm)
min.
A B
upper cabinet and
side cabinet depth
24"
(61 cm)
typical*
60" ( 152.4 cm) min.
10
"
10
"
26.2cm
26.2cm
cm)29 " (76.0
18"
45.5cm
Electrical Requirements
Observe all governing codes and ordinances.
Required:
A 120 V, 60 Hz, AC only, 15 or 20 A electrical supply with a
fuse or circuit breaker
Recommended:
A time-delay fuse or time-delay circuit breaker
A separate circuit serving only this microwave oven
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.
Failure to follow these instructions can result in death,
fire, or electrical shock.
WARNING
GROUNDING INSTRUCTIONS
SAVE THESE INSTRUCTIONS
For all cord connected appliances:
The microwave oven must be grounded. In the event of
an electrical short circuit, grounding reduces the risk of
electric shock by providing an escape wire for the electric
current. The microwave oven is equipped with a cord
having a grounding wire with a grounding plug. The plug
must be plugged into an outlet that is properly installed
and grounded.
WARNING:
Improper use of the grounding plug can
result in a risk of electric shock. Consult a qualified
electrician or serviceman if the grounding instructions are
not completely understood, or if doubt exists as to whether
the microwave oven is properly grounded.
Do not use an extension cord. If the power supply cord is
too short, have a qualified electrician or serviceman install
an outlet near the microwave oven.
**24” (61 cm) is typical for 60” (152.4 cm) installation height
Exact dimensions may vary depending on type of range/
cooktop below.
NOTE: To ensure good performance, do not obstruct top vent
airflow. If cabinets are deeper than 14" (35.6 cm) but no more
than 15" (38.1cm), use the bump out mounting kit replacing the
mounting plate from the wall. The bump out mounting kit (part #
W11185746) is not provided but can be purchased from
Whirlpool.
12"
DEEPER
14"
14"
DEEPER
15"
mounting plate
Bump out mounting
bracket
Product Dimensions