Installation Instruction

5
Vent Cover Installation
(for both upper vent and wall vent installation)
1. Remove screws attaching B and C cover. Slide them out.
Keep C for step 2 use.
NOTE: Keep B for future recirculation vent installation.
2. Rotate C 180 degrees, place it as shown below.
3. Take J from packaging upper foam (see item in “Parts
Supplied” section), attach both of them as shown below with
screws removed from step 1.
Locate Wall Stud(s)
NOTE: If no wall studs exist within the cabinet opening, do not
install the microwave oven.
See illustrations in “Possible Wall Stud Congurations.”
1. Using a stud nder, locate the edges of the wall stud(s)
within the opening.
2. Mark the center of each stud and draw a plumb line down
each stud center. See illustrations in “Possible Wall Stud
Congurations.”
A. Screws
B. Recirculation vent covers
C. Recirculation lighting cover
B
B
C
A
180°
C
C. Recirculation lighting cover
J
A
A. Screws
J. Exhaust vent covers