Dimension Guide

27" (68.6 CM) AND 30" (76.2 CM) ELECTRIC SINGLE AND DOUBLE BUILT-IN OVEN
PRODUCT MODEL NUMBERS
KODE300E
KODE307E
KODE500E
KODE507E
PRODUCT DIMENSIONS
27" (68.6 cm) models
A. 28¾" (72.8 cm) max. overall
height
B. 257⁄16" (64.6 cm) max. recessed
width
C. 26³⁄4" (67.9 cm) recessed
height
D. 23¹⁄4" (59.1 cm) max. recessed
depth
E. 27" (68.6 cm) overall width
F. 12" (30.5 cm) from back of
control panel to start of strain
relief
G. 48" (121.9 cm) exible conduit
length
Page 1 of 2
KODT100E
KODT107E
KOSE500E
KOSE507E
KOST100E
KOST107E
KEBS109E
KEBS209E
KEBS207E
Electrical: To properly install your oven, you must determine the type
of electrical connection you will be using and follow the instructions
provided for it here.
Oven must be connected to the proper electrical voltage and
frequency as specied on the model/serial number rating plate.
The model/serial number rating plate is located under the control
panel on single ovens and under the control panel on the upper
oven cavity on double ovens. See the following illustrations.
art
Single Oven Double Oven
A. Model/serial number plate A. Model/serial number plate
Models rated from 7.3 to 9.6 kW at 240 volts (5.4 to 7.4 kW at 208
volts) require a separate 40-amp circuit. Models rated at 4.8 kW
and below at 240 volts (3.6 kW and below at 208 volts) require a
separate 20-amp circuit.
A circuit breaker is recommended.
Connect directly to the circuit breaker box (or fused disconnect)
through exible, armored or nonmetallic sheathed, copper cable
(with grounding wire). See “Make Electrical Connection” section.
Flexible conduit from the oven should be connected directly to the
junction box.
Fuse both sides of the line.
Do not cut the conduit. The length of conduit provided is for
serviceability of the oven.
A UL listed or CSA approved conduit connector must be provided.
If the house has aluminum wiring, follow the procedure below:
1. Connect a section of solid copper wire to the ends of the
exible conduit leads.
2. Connect the aluminum wiring to the added section of copper
wire using special connectors and/or tools designed and UL
listed for joining copper to aluminum.
Follow the electrical connector manufacturer's recommended
procedure. Aluminum/copper connection must conform with local
codes and industry accepted wiring practices.
For power requirements for models KOST107E, KOST100E,
KOSE507E, KOSE500E, KODE307E, KODE300E, KODE507E,
KODE500E, KODT100E and KODT107E, refer to the following table.
Voltage Single
Thermal
Single
Convect
Double
Thermal
Double
Convect
Double
Convect/
Thermal
240 VAC 4100 W 4100 W 8163 W 8300 W 8300 W
208 VAC 3100 W 3100 W 6300 W 6300 W 6300 W
240 VAC 17.2 A 17.2 A 34.2 A 34.2 A 34.2 A
208 VAC 15.0 A 15.0 A 29.9 A 29.9 A 29.9 A
30" (76.2 cm) models
A. 28¾" (72.8 cm) max. overall
height
B. 28½" (72.4 cm) max. recessed
width
C. 26³⁄4" (67.9 cm) recessed height
D. 23¹⁄4" (59.1 cm) max. recessed
depth
E. 30" (76.2 cm) overall width
F. 12" (30.5 cm) from back of
control panel to start of strain
relief
G. 48" (121.9 cm) exible conduit
length
art
27" (68.6 cm) models
A. 51³⁄16" (130.0 cm)
max. overall height
B. 257⁄16" (64.6 cm)
max. recessed width
C. 48¹³⁄16" (124.0 cm)
recessed height
D. 23¹⁄4" (59.1 cm)
max. recessed depth
E. 27" (68.6 cm) overall width
F. 12" (30.5 cm) from back
of control panel to start
of strain relief
G. 66" (167.6 cm) exible
conduit length
30" (76.2 cm) models
A. 51³⁄16" (130.0 cm)
max. overall height
B. 28½" (72.4 cm)
max. recessed width
C. 48¹³⁄16" (124.0 cm)
recessed height
D. 23¹⁄4" (59.1 cm)
max. recessed depth
E. 30" (76.2 cm) overall width
F. 12" (30.5 cm) from back
of control panel to start
of strain relief
G. 66" (167.6 cm) exible
conduit length
Ref. W10725670B
05/15
C
B
A
E
D
G
F
B
D
E
A
C
G
F
A
A