Owner's Manual
Table Of Contents
- BUILT-IN OVEN SAFETY
- Built-In Oven Safety
- OVEN MAINTENANCE AND CARE
- General Cleaning
- Self-Cleaning Cycle
- Steam Clean (on some models)
- INSTALLATION INSTRUCTIONS
- REQUIREMENTS
- Tools and Parts
- Location Requirements
- Electrical Requirements
- INSTALLATIONS
- Prepare Built-In Oven
- Remove Oven Door(s)
- Positioning Oven Feet for Multiple Cabinet Cutout Heights
- Make Electrical Connection
- Install Oven
- Install Deflector Kit (on some models)
- Replace Oven Door(s)
- Complete Installation
- SÉCURITÉ DU FOUR ENCASTRÉ
- Sécurité du four encastré
- ENTRETIEN ET RÉPARATION DU FOUR
- Nettoyage général
- Programme d’autonettoyage
- Steam Clean (nettoyage à la vapeur) (sur certains modèles)
- INSTRUCTIONS D’INSTALLATION
- SPÉCIFICATIONS
- Outils et pièces
- Exigences d’emplacement
- Spécifications électriques
- INSTALLATION
- Préparer le four encastré
- Enlever la/les porte(s) du four
- Positionner les pieds du four pour des ouvertures de découpe dans l’armoire
- Raccordement électrique
- Installation du four
- Installation de l’ensemble de déflecteurs (sur certains modèles)
- Réinstallation de la/des porte(s) du four
- Achever l’installation
- SEGURIDAD DEL HORNO INTEGRADO
- Seguridad del horno integrado
- MANTENIMIENTO Y CUIDADO DEL HORNO
- Limpieza general
- Ciclo de autolimpieza
- Steam Clean (Limpieza con vapor) (en algunos modelos)
- INSTRUCCIONES DE INSTALACIÓN
- REQUISITOS
- Herramientas y piezas
- Requisitos de ubicación
- Requisitos eléctricos
- INSTALACIONES
- Preparación del horno empotrado
- Retire las puertas del horno
- Ubicación de las patas del horno para múltiples alturas de corte del armario
- Hacer la conexión eléctrica
- Para instalar el horno
- Instale el kit de deflector (en algunos modelos)
- Vuelva a colocar las puertas del horno
- Finalización de la instalación
10
Single Ovens Undercounter - without cooktop
installed above
Front View
27" (68.6 cm) Models
A. Recommended junction box
location
B. 3/4" (1.9 cm) top cleat*
C. 27
1
/
4
" (69.2 cm) minimum width
of flush inset cutout
D. 25
7
/
8
" (65.7 cm) minimum width
of opening
E. 29
1
/
4
" (74.3 cm) minimum
height of flush inset cutout
F. 28
1
/
2
" (72.4 cm) recommended
cutout height
G. 11/16" (1.7 cm) side cleat*
H. 1/4" x 2" (6.4 mm x 5.1 cm)
spacer the entire depth of the
cabinet*
I. 4
5
/
8
" (11.7 cm) bottom of cutout
to floor
30" (76.2 cm) Models
A. Recommended junction box
location
B. 3/4" (1.9 cm) top cleat*
C. 30
1
/
4
" (76.8 cm) minimum width
of flush inset cutout
D. 28
7
/
8
" (73.3 cm) minimum width
of opening
E. 29
1
/
4
" (74.3 cm) minimum
height of flush inset cutout
F. 28
1
/
2
" (72.4 cm) recommended
cutout height
G. 11/16" (1.7 cm) side cleat*
H. 1/4" x 2" (6.4 mm x 5.1 cm)
spacer the entire depth of the
cabinet*
I. 4
5
/
8
" (11.7 cm) bottom of cutout
to floor
*Cleats and spacers must be recessed 1
3
/
8
" (3.5 cm) from the
front of the cabinet.
Top View
27" (68.6 cm) Models
A. 2" (5.1 cm) spacer the entire
depth of the cutout*
B. 25" (63.5 cm) depth of cutout
C. 1
3
/
8
" (3.5 cm) recess from front
of cabinet
D. 11/16" (1.7 cm) side cleat*
30" (76.2 cm) Models
A. 2" (5.1 cm) spacer the entire
depth of the cutout*
B. 25" (63.5 cm) depth of cutout
C. 1
3
/
8
" (3.5 cm) recess from front
of cabinet
D. 11/16" (1.7 cm) side cleat*
*Cleats and spacers must be recessed 1
3
/
8
" (3.5 cm) from the
front of the cabinet.
Cabinet Dimensions - Double Ovens, Flush
Installations
NOTE: This is an alternate option to install your product in the
cabinet and obtain a flush look. For standard installation, refer
section “Cabinet Dimensions - Double Ovens, Standard
Installation”.
A 25
3
/
8
" (64.4 cm) minimum cutout depth is required.
Top and bottom gaps with be 1/8" (0.3 cm) gap above and below
the product. Top and bottom gaps not required for installation.
Exposed areas of the cabinet should be finished to match.
Double Ovens Installed in Cabinet
Front View Side View
27" (68.5 cm) Models
A. 3/4" (1.9 cm) top cleat*
B. 27
1
/
4
" (69.2 cm) minimum
width of flush inset cutout
C. 25
7
/
8
" (65.7 cm) minimum
width of opening
D. 52" (132.1 cm) minimum
height of flush inset cutout
E. 51
1
/
4
" (130.1 cm)
recommended cutout height
F. 11/16" (1.7 cm) side cleat*
G. 1/4" (0.6 cm) recommended
with foot. 15/16" to 1
1
/
16
"
(2.2 cm to 2.8 cm) allowable
without foot.
H. Recommended junction box
location
I. 4
5
/
8
" - 14
3
/
4
" (11.7 - 37.5 cm)
bottom of cutout to floor
J. 25" (63.5 cm) minimum depth
of cutout
30" (76.2 cm) Models
A. 3/4" (1.9 cm) top cleat*
B. 30
1
/
4
" (76.8 cm) minimum
width of flush inset cutout
C. 28
7
/
8
" (73.3 cm) minimum
width of opening
D. 52" (132.1 cm) minimum
height of flush inset cutout
E. 51
1
/
4
" (130.1 cm)
recommended cutout height
F. 11/16" (1.7 cm) side cleat*
G. 1/4" (0.6 cm) recommended
with foot. 15/16" to 1
1
/
16
"
(2.2 cm to 2.8 cm) allowable
without foot.
H. Recommended junction box
location
I. 4
5
/
8
" - 32" (11.7 - 81.3 cm)
bottom of cutout to floor
J. 25" (63.5 cm) minimum depth
of cutout
*Cleats and spacers must be recessed 1
3
/
8
" (3.5 cm) from the
front of the cabinet.