Owner's Manual
Table Of Contents
- BUILT-IN OVEN SAFETY
- Built-In Oven Safety
- OVEN MAINTENANCE AND CARE
- General Cleaning
- Self-Cleaning Cycle
- Steam Clean (on some models)
- INSTALLATION INSTRUCTIONS
- REQUIREMENTS
- Tools and Parts
- Location Requirements
- Electrical Requirements
- INSTALLATIONS
- Prepare Built-In Oven
- Remove Oven Door(s)
- Positioning Oven Feet for Multiple Cabinet Cutout Heights
- Make Electrical Connection
- Install Oven
- Install Deflector Kit (on some models)
- Replace Oven Door(s)
- Complete Installation
- SÉCURITÉ DU FOUR ENCASTRÉ
- Sécurité du four encastré
- ENTRETIEN ET RÉPARATION DU FOUR
- Nettoyage général
- Programme d’autonettoyage
- Steam Clean (nettoyage à la vapeur) (sur certains modèles)
- INSTRUCTIONS D’INSTALLATION
- SPÉCIFICATIONS
- Outils et pièces
- Exigences d’emplacement
- Spécifications électriques
- INSTALLATION
- Préparer le four encastré
- Enlever la/les porte(s) du four
- Positionner les pieds du four pour des ouvertures de découpe dans l’armoire
- Raccordement électrique
- Installation du four
- Installation de l’ensemble de déflecteurs (sur certains modèles)
- Réinstallation de la/des porte(s) du four
- Achever l’installation
- SEGURIDAD DEL HORNO INTEGRADO
- Seguridad del horno integrado
- MANTENIMIENTO Y CUIDADO DEL HORNO
- Limpieza general
- Ciclo de autolimpieza
- Steam Clean (Limpieza con vapor) (en algunos modelos)
- INSTRUCCIONES DE INSTALACIÓN
- REQUISITOS
- Herramientas y piezas
- Requisitos de ubicación
- Requisitos eléctricos
- INSTALACIONES
- Preparación del horno empotrado
- Retire las puertas del horno
- Ubicación de las patas del horno para múltiples alturas de corte del armario
- Hacer la conexión eléctrica
- Para instalar el horno
- Instale el kit de deflector (en algunos modelos)
- Vuelva a colocar las puertas del horno
- Finalización de la instalación
9
Cabinet Dimensions - Double Ovens, Standard
Installation
Double Ovens Installed in Cabinet
27" (68.6 cm) models
A. 27" (68.6 cm) minimum
cabinet width
B. 1" (2.5 cm) top of cutout to
bottom of upper cabinet door
C. 14
3
/
4
" (37.5 cm) bottom of
cutout to floor is
recommended.
7.5"-14
3
/
4
" (19.1 cm - 37.5 cm)
bottom of cutout to floor is
acceptable.
D. 25
1
/
2
" (64.8 cm) minimum
cutout width
E. 1
1
/
2
" (3.8 cm) minimum bottom
of cutout to top of cabinet door
F. 50
1
/
4
" (127.6 cm)*
recommended cutout height
G. 24" (60.7 cm) cutout depth
30" (76.2 cm) models
A. 30" (76.2 cm) minimum
cabinet width
B. 1" (2.5 cm) top of cutout to
bottom of upper cabinet door
C. 14
3
/
4
" (37.5 cm) bottom of
cutout to floor is
recommended.
7.5"-14
3
/
4
" (19.1 cm - 37.5 cm)
bottom of cutout to floor is
acceptable.
D. 28
1
/
2
" (72.4 cm) minimum
cutout width
E. 1
1
/
2
" (3.8 cm) minimum
bottom of cutout to top of
cabinet door
F. 50
1
/
4
" (127.6 cm)*
recommended cutout height
G. 24" (60.7 cm) cutout depth
*NOTE: The cutout height can be between 50" and 52
3
/
16
"
(127 cm and 132.6 cm) for double ovens.
NOTE: Contact service to get tall shield for cutouts greater than
50
3
/
8
" (128 cm) to enhance installation
Cabinet Dimensions - Single Ovens, Flush
Installations
NOTE: This is an alternate option to install your product in the
cabinet and obtain a flush look. For standard installation, refer
section “Cabinet Dimensions - Single Ovens, Standard
Installation”.
A 25" (63.5 cm) minimum cutout depth is required.
Top and bottom gaps with be 1/8" (0.3 cm) gap above and below
the product. Top and bottom gaps not required for installation.
Exposed areas of the cabinet should be finished to match.
Single Ovens Installed in Cabinet
Front View Side View
27" (68.6 cm) Models
A. 3/4" (1.9 cm) top cleat*
B. 27
1
/
4
" (69.2 cm) minimum width
of flush inset cutout
C. 25
7
/
8
" (65.7 cm) minimum width
of opening
D. 29
1
/
4
" (74.3 cm) minimum
height of flush inset cutout
E. 28
1
/
2
" (72.4 cm) recommended
cutout height
F. 11/16" (1.7 cm) side cleat*
G. 1/4" (0.6 cm) recommended
with foot. 15/16" to 1
1
/
8
"
(2.2 cm to 2.9 cm) allowable
without foot.
H. Recommended junction box
location
I. 4
5
/
8
"- 32" (11.7 - 81.3 cm)
bottom of cutout to floor
J. 25" (63.5 cm) minimum depth of
cutout
30" (76.2 cm) Models
A. 3/4" (1.9 cm) top cleat*
B. 30
1
/
4
" (76.8 cm) minimum width
of flush inset cutout
C. 28
7
/
8
" (73.3 cm) minimum width
of opening
D. 29
1
/
4
" (74.3 cm) minimum
height of flush inset cutout
E. 28
1
/
2
" (72.4 cm) recommended
cutout height
F. 11/16" (1.7 cm) side cleat*
G. 1/4" (0.6 cm) recommended
with foot. 15/16" to 1
1
/
8
"
(2.2 cm to 2.9 cm) allowable
without foot.
H. Recommended junction box
location
I. 4
5
/
8
" - 32" (11.7 - 81.3 cm)
bottom of cutout to floor
J. 25" (63.5 cm) minimum depth of
cutout
*Cleats and spacers must be recessed 1
3
/
8
" (3.5 cm) from the
front of the cabinet.