Dimension Guide

3
Electrical: A 115 V, 60 Hz., AC only, 15 A or 20 A fused, grounded electrical
supply is required. It is recommended that a separate circuit serving only your
refrigerator be provided. Use an outlet that cannot be turned off by a switch. Do
not use an extension cord.
NOTE: Before performing any type of installation, cleaning, or removing a light
bulb, turn the control (Thermostat, Refrigerator or Freezer Control depending
on the model) to OFF and then disconnect the refrigerator from the electrical
source. When you are nished, reconnect the refrigerator to the electrical
source and reset the control (Thermostat, Refrigerator or Freezer Control
depending on the model) to the desired setting. See “Using the Controls.”
Water: A cold water supply with water pressure between 30 psi and 120 psi
(207 kPa and 827 kPa) is required to operate ice maker and water dispenser.
If you have questions about your water pressure, call a licensed, qualied
plumber.
IMPORTANT: The pressure of the water coming out of a reverse osmosis
system going to the water inlet valve of the refrigerator needs to be between
30psi and 120 psi (207 kPa and 827 kPa).
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.
Failure to follow these instructions can result in death,
fire, or electrical shock.
WARNING
Power Cord
Location
Power Cord
Model Size Type Length
KRSC700
KRSC703
KRSF705
Standard
75
5
/
8
"
(1920 mm)
Water Lines:
are not foamed in and
are external
Side By Side Refrigerator