Instruction for Use

Installation
17
A) Installation next to kitchen units or cabinets
To allow complete 90° opening of the door, install the product ensuring a space of at least 3.5 mm
between the side flanges and the doors of any adjacent kitchen units/cabinets or electrical appliances (as
shown in figure 1).
B) Installation next to walls
To allow complete 90° opening of the door, install the product ensuring a space of at least 60 mm between
the side flange and the adjacent wall (as shown in figure 2).
60 mm
Fig. 1
Fig. 2
FLANGE
CABINET
DOOR
CABINET
DOOR
WALL
FLANGE