Dimension Guide

30" (76.2 cm) Slide-In Dual Fuel Range
PRODUCT MODEL NUMBERS PRODUCT DIMENSIONS
KSDB900E
Natural Gas:
This range is factory set for use with Natural gas. See “Gas
Conversions” section. The model/serial/rating plate located on the
oven frame behind the top right-hand side of the oven door has
information on the types of gas that can be used. If the types of gas
listed do not include the type of gas available, check with the local
gas supplier.
LP gas conversion:
Conversion must be done by a qualified service technician.
No attempt shall be made to convert the appliance from the gas
specified on the model/serial/rating plate for use with a different gas
without consulting the serving gas supplier. See “Gas Conversions”
section.
Gas Supply Line
Provide a gas supply line if ¾" (1.9 cm) rigid pipe to the range
location. A smaller pipe on longer runs may result in insuffient
gas supply. With LP gas, piping or tubing size can be ½" (1.3 cm)
minimum. Usually, LP gas suppliers deteremine the size and materials
used in the system.
NOTE: Pipe-joint compounds that resist the action of LP gas must be
used. Do not use TEFLON
®†
tape.
If local codes permit, a new CSA design-certified, 4 to 5 ft (122 to
152.4 cm) long, ½" (1.3 cm) or ¾" (1.9 cm) I.D. (inside diameter),
flexible metal appliance connector may be used for connecting range
to the gas supply line.
Must include a shutoff valve:
The supply line must be equipped with a manual shutoff valve. This
valve should be located in the same room but external to the range
opening, such as an adjacent cabinet. It should be in a location that
allows ease of opening and closing. Do not block access to shutoff
valve. The valve is for turning on or shutting off gas to the range.
†®TEFLON is a registered trademark of E.I. Du Pont Nemours and Company.
A.
1
3
\16" (3.0 cm) height from
cooktop to top of vent
B. 29
7
\8" (75.9 cm)
C. Model/serial/rating plate
(located behind the oven
door on the top right-hand
side of the oven frame)
D. 36" (91.4 cm) height to
top of cooktop edge with
leveling legs screwed in all
the way*
E. 28
5
\16" (71.9 cm) max. depth
from front of console to
back of range
F. 28
7
\8" (73.3 cm) max. depth
from handle to back of
range
IMPORTANT: Range must be level after installation. Follow
the instructions in the “Level Range” section. Using the cooktop
as a reference for leveling the range is not recommended.
* Range can be raised approximately 1" (2.5 cm) by adjusting
the leveling legs.
Because Whirlpool Corporation includes a continues commitment to improve our
products, we reserve the right to change materials and specifications without notice.
Dimensions are for planning purposes only. For complete details, see Installation
Instructions packed with product. Specifications subject to change without notice.
GAS SUPPLY REQUIREMENTS
This range is manufactured with the neutral terminal connected to
the cabinet. Use a 3-wire UL listed, 40- or 50-amp power supply cord
(pigtail). See the following Range Rating chart. If local codes do not
permit ground through the neutral, use a 4-wire power supply cord
rated at 250 volts, 40 or 50 amps and investigated for use with ranges.
ELECTRICAL REQUIREMENTS
Range Rating* Specified Rating of Power
Supply Cord Kit and Circuit
Protection
120/240 Volts 120/208 Volts Amp
8.8 - 16.5 KW 7.8 - 12.5 KW 40 or 50**
16.6 - 22.5 KW 12.6 - 18.5 KW 50
* The NEC calculated load is less than the total connected load listed
on the model/serial/rating plate.
** If connecting to a 50-amp circuit, use a 50-amp rated cord with kit.
For 50-amp rated cord kits, use kits that specify use with a nominal
1
3
/8" (3.5 cm) diameter connection opening.
A circuit breaker is recommended.
B
D
A
F
E
C
Ref. W10665259D
8/10/15
Page 1 of 2