Use and Care Guide
7
®
NSF is a registered trademark of NSF International.
Ice Maker Water Filtration System
Model P6GEG2KL, P6KG2KL, P6WG2KL Capacity 2000 Gallons (7571 Liters)
This system has been tested according to NSF/ANSI Standards 42 for the reduction of the substances listed below. The concentration of the
indicated substances in water entering the system was reduced to a concentration less than or equal to the permissible limit for water leaving the
system, as specied in NSF/ANSI Standards 42.
Substance Reduction
Aesthetic Effects
NSF Reduction
Requirements
Average
Inuent
Inuent Challenge
Concentration
Maximum
Efuent
Average
Efuent
Minimum %
Reduction
Average %
Reduction
Chlorine Taste/Odor 50% reduction 1.9727 mg/L 2.0 mg/L ± 10% 0.71 mg/L 0.7788 mg/L 70.2 72.81
Test Parameters: pH = 7.5 ± 0.5 unless otherwise noted. Flow = 0.50 gpm (1.89 Lpm). Pressure = 60 psig (413.7 kPa).
Temp. = 68°F to 71.6°F (20°C to 22°C). Rated service capacity = 2000 gallons (7571 liters).
System tested and certified by NSF
International against NSF/ANSI
Standard42 for the reduction of
Chlorine Ta ste and Odor.
PERFORMANCE DATA SHEET
■ It is essential that operational, maintenance, and lter
replacement requirements be carried out for the product to
perform as advertised.
■ Use replacement lter P6RFWG2K, P6RFGEG2K, P6RFKG2K,
Part Number ICE2.
Style 1 – When the water lter status display changes from
“GOOD” to “ORDER,” order a new lter. When the lter
indicator reads “REPLACE,” it is recommended that you
replace the lter.
Style 2 – Press FILTER to check the status of your water lter.
If the lter indicator light is yellow and the words “ORDER
FILTER” appear on the display screen, order a new lter. If the
lter indicator light is red, it is recommended that you replace
the lter.
■ These contaminants are not necessarily in your water supply.
While testing was performed under standard laboratory
conditions, actual performance may vary.
■ The product is for cold water use only.
■ Do not use with water that is microbiologically unsafe or of
unknown quality without adequate disinfection before or after
the system.
■ Refer to the “Warranty” section for the Manufacturer’s name,
address and telephone number.
■ Refer to the “Warranty” section for the Manufacturer’s limited
warranty.
Application Guidelines/Water Supply Parameters
Water Supply City or Well
Water Pressure 30 - 120 psi (207 - 827 kPa)
Water Temperature 33°- 100°F (0.6° - 37.8°C)
Service Flow Rate 0. 50 gpm (1.89 Lpm) @ 60 psi