INSTALLATION REQUIREMENTS
Tools and Parts
Gather the required tools and parts before starting installation.
Read and follow the instructions provided with any tools listed
here.
NOTE: This range hood is recommended for use with cooking
surfaces according to the following:
36" (91.4 cm) or 48" (122 cm) range hoods with 1 motor
(585CFM) to be paired with maximum total rating of
90,000BTU.
36" (91.4 cm) or 48" (122 cm) range hoods with 2 motors
(1170CFM) to be paired with maximum total rating of
105,000BTU.
Tools needed
Level
Drill
1
1
/
4
" (3 cm) drill bit
3/32" (2.4 mm) drill bit if installing into wood
Pencil
Wire stripper or utility knife
Tape measure or ruler
Pliers
Caulking gun and weatherproof caulking compound
Vent clamps
Jigsaw or keyhole saw
Flat-blade screwdriver
Metal snips
Phillips screwdriver
Scissors
Parts needed
Home power supply cable
1/2" (1.3 cm) UL listed or CSA approved strain relief
Three UL listed wire connectors
One wall or roof cap
Metal vent system
Two 175 W max heat lamp bulbs
Blower motor system—internal or external
Parts supplied
Remove parts from packages. Check that all parts are included.
Two metal grease lters for 36" (91.4 cm) models
Three metal grease lters for 48" (121.9 cm) models
Two vent cover support brackets
Two 4.5 x 13 mm screws
Two 10 x 50 mm mounting screws
Two 8 x 40 mm mounting screws
Two D5.3 x 20 mm washers
Four 5 x 45 mm screws
Six 4.2 x 8 mm screws
T-20 TORX
adapter
Location Requirements
IMPORTANT: Observe all governing codes and ordinances.
Have a qualied technician install the range hood. It is the
installer’s responsibility to comply with installation clearances
specied on the model/serial rating plate. The model/serial rating
plate is located inside the range hood on the rear wall of the
range hood.
Range hood location should be away from strong draft areas,
such as windows, doors, and strong heating vents.
Cabinet opening dimensions that are shown must be used.
Given dimensions provide minimum clearance.
The range hood is factory set for venting through the roof or
through the wall.
All openings in ceiling and wall where range hood will be
installed must be sealed.
For Mobile Home Installations
The installation of this range hood must conform to the
Manufactured Home Construction Safety Standards, Title
24CFR, Part 328 (formerly the Federal Standard for Mobile
Home Construction and Safety, Title 24, HUD, Part 280) or when
such standard is not applicable, the standard for Manufactured
Home Installation 1982 (Manufactured Home Sites, Communities
and Setups) ANSI A225.1/NFPA 501A, or latest edition, or with
local codes.
Product Dimensions
Vented Installations
36" (91.4 cm)
or 48" (121.9 cm)
25" 63.5 cm)
7
7
/
8
" (20.0 cm)
11
5
/
16
" (28.7 cm)
24½" (62.3 cm) min.
327⁄16
" (82.4 cm) max.
22
3
/
4
" (57.8 cm)
†TORX
®