Owner's Manual
Table Of Contents
- Vent System Safety
- Installation Requirements
- Installation Instructions INTERIOR-MOUNTED VENT MOTOR
- INSTALLATION INSTRUCTIONS EXTERIOR-MOUNTED VENT MOTOR
- VENT SYSTEM USE
- VENT SYSTEM CARE
- Troubleshooting
- Wiring Diagrams
- Assistance or service
- SÉCURITÉ DU SYSTÈME DE VENTILATION
- EXIGENCES D'INSTALLATION
- INSTRUCTIONS D’INSTALLATION VENTILATEUR MONTÉ À L’INTÉRIEUR
- INSTRUCTIONS D’INSTALLATION VENTILATEUR MONTÉ À L’EXTÉRIEUR
- Méthodes d’évacuation
- Installation du conduit d’évacuation
- Achever l’installation
- Installation du ventilateur en ligne (type externe) du système d’extraction par le bas
- Raccordements électriques du système de ventilation en ligne
- Raccordement de l’alimentation électrique au système d’extraction par le bas
- Contrôle du fonctionnement
- UTILISATION DU SYSTÈME D’EXTRACTION
- ENTRETIEN DU SYSTÈME D’ÉVACUATION
- Dépannage
- SCHÉMA DE CÂBLAGE
- ASSISTANCE OU SERVICE
9
INSTALLATION INSTRUCTIONS
INTERIOR-MOUNTED VENT MOTOR
Venting Methods
Determine which venting method is best for your application.
Vent system can terminate either through the wall or oor.
Island Location
NOTE: For island locations, a front- or rear-mounted blower
motor can also be mounted for right or left venting if needed for
your application. Most island applications would still require the
venting to be directed down through the oor.
Built-In Cabinet Locations
Island Location - Vent System Installed Under
a Concrete Slab Using PVC Sewer Pipe
Front-Mounted (Standard) Blower Motor
Rear-Mounted Blower Motor
Calculating Vent System Length
3¼" x 10" (8.3 cm x 25.4 cm) rectangular vent is required from
the blower motor box. It can be transitioned to 6" (15.2 cm)
round vent if needed.
Maximum Length of Vent System
Vent Length
6" (15.2 cm) round 35 ft (8.9 m)
3
1
/
4
" x 10" (8.3 cm x 25.4 cm) 35 ft (8.9 m)
To calculate the length of the system you need, add the
equivalent feet (meters) for each vent piece used in the system.
Front-Mounted (Standard)
Blower Motor
Rear-Mounted Blower Motor
A
A
A. Down vent
B
C
A
A. Down vent
B. Left vent
C. Right vent
A
B
C
D
E
F
G
H
I
J
K
L
M
A
B
C
D
E
F
G
H
I
J
K
L
M
A. Wall cap
B. 6" (15.2 cm) round metal vent
C. 16" (40.6 cm) maximum
D. 6" (15.2 cm) round PVC sewer pipe
E. 6" (15.2 cm) round metal vent transition with damper (supplied)
F. 6" (15.2 cm) round PVC coupling
G. Concrete slab
H. 6" (15.2 cm) round PVC sewer pipe
I. 6" (15.2 cm) round 90° PVC sewer pipe elbow
J. Tightly pack gravel or sand completely around pipe.
K. 6" (15.2 cm) round 90° PVC sewer pipe elbow
L. 6" (15.2 cm) round PVC coupling
M. 12" (30.5 cm) minimum