Installation Instructions

14
3. Use UL listed wire connectors and connect black wires (B)
together.
4. Use UL listed wire connectors and connect white wires (A)
together.
NOTE: When using an in-line blower motor system, the
green (or green/yellow) ground wire in the conduit from the
in-line blower motor system is to be connected with the
green (or bare) wire of the home power supply cable and with
the green/yellow wire (D) in the terminal box.
5. Connect green (or bare) ground wire from home power
supply to the green/yellow ground wire (D) in terminal box
using UL listed wire connectors.
6. Install terminal box cover.
7. Check that all light bulbs are secure in their sockets.
8. Reconnect power.
Complete Installation and Check
Operation
1. Install grease lters. See the “Range Hood Care” section.
2. Check operation of the range hood blower and lights. See
the “Range Hood Use” section.
3. If the range hood does not operate, check to see whether a
circuit breaker has tripped or a household fuse has blown.
Disconnect power supply and check that the wiring is
correct.
NOTE: To get the most efcient use from your new hood
liner, read the “Range Hood Use” section.
WARNING
Electrical Shock Hazard
Electrically ground blower.
Connect ground wire to green and yellow ground wire
in terminal box.
Failure to do so can result in death or electrical shock.
C
AA
A
A
B
D
E
A. Halogen lights
B. Halogen light switch
C. Blower control switches
D. Grease lter handle
E. Grease lter
A
B
C
D
E
F
A. White wires
B. Black wires
C. UL listed wire connectors
D. Green, bare or yellow/green wires
E. Home power supply
F. UL listed or CSA approved 1/2" (13 mm) strain relief