Installation Clearances
Venting System
Venting Methods
NOTES:
Flexible vent is not recommended. Flexible vent
createsbothback pressure and air turbulence
thatgreatlyreduce performance.
The vent system is optional for this model.
Vent system can terminate either through the roof or wall.
Use3
1
/
4
" x 10" (8.3 x 25.4 cm) rectangular with a maximum
ventlength of 35 ft (10.7 m).
Top Venting Wall Venting
A
B
A
B
A. 3
1
/
4
" x 10" (8.3 x 25.4 cm)
rectangular vent through the
roof (purchased separately)
B. Roof cap with damper
(purchased separately)
A. 3
1
/
4
" x 10" (8.3 x 25.4 cm)
rectangular vent through
thewall or out the top
(purchased separately)
B. Wall cap with damper
(purchased separately)
Cold Weather Installations
An additional backdraft damper should be installed to
minimizebackward cold air ow and a thermal break should
beinstalled to minimize conduction of outside temperatures
aspart of the vent system. The damper should be on the cold
airside of the thermal break.
The break should be as close as possible to where the
ventsystem enters the heated portion of the house.
Makeup Air
Local building codes may require the use of makeup
airsystemswhen using ventilation systems greater than
speciedCFM of air movement. The specied CFM varies
fromlocale to locale. Consult your HVAC professional
forspecic requirements in your area.
Venting Requirements
Vent system must terminate to the outdoors, except
fornon-vented (recirculating) installations.
Do not terminate the vent system in an attic
orotherenclosed area.
Do not use a 4" (10.2 cm) laundry-type wall cap.
Use 3
1
/
4
" x 10" (8.3 x 25.4 cm) rectangular metal
vent,depending on your installation requirement.
Rigidmetalvent is recommended. Plastic or metal
foilventisnotrecommended.
The length of vent system and number of elbows should
bekept to a minimum to provide efcient performance.
For the most efcient and quiet operation:
Use no more than three 90° elbows.
Make sure there is a minimum of 24" (61 cm) of straight
ventbetween the elbows if more than 1 elbow is used.
Do not install 2 elbows together.
Use clamps or duct tape to seal all joints in the vent system.
The vent system must have a damper. If roof or wall cap has
a damper, do not use damper supplied with the range hood.
Use caulking to seal exterior wall or roof opening
aroundthecap.
B
A
C
D
E
A. 24" (61 cm) minimum distance from electric cooking surface
24" (61 cm) minimum distance from gas cooking surface
30" (76.2 cm) suggested maximum above the cooking surface
B. 18" (45.7 cm) minimum clearance - upper cabinet to countertop
C. 30" (76.2 cm) minimum cabinet opening width for 30"
(76.2cm) models and 36" (91.4 cm) minimum cabinet
widthfor36"(91.4cm) models
D. 12" (30.5 cm) cabinet depth
E. 36" (91.4 cm) base cabinet height