ICE MAKER SERVICE SHEET
SPECIFICATIONS:
THERMISTOR INPUT TO CONTROL: - CLOSE -8.1°C(17.4°) OR AFTER 100
MIN
WATER FILL - 117 CC( ) 13.5 SEC.
CYCLE - ONE TWIST PROCESS
INPUT VOLTAGE: 120 & 240 V MODELS
NOTE: 24 HOURS ICE MAKER MAKE 56 TO 73 ICE CUBES
THE ICE MAKER REQUIRED 2-3 DAYS TO FILL THE ICE BIN CONTAINER.
(THE ICE MAKER REQUIRED 3 OURS TO ESTABILIZATION)
SERVICE PROCEDURE
MODULE MOTOR -
THE ON/OFF SWITCH (MAIN SWITCH) AND THE TEST SWITCH ARE
LOCATED AT THE BOTTOM OF THE ICE MAKER.
MAIN SWITCH -
TURN THE MAIN SWITCH TO ON POSITION (AS SHOWN IN THE PICTURE
BELOW), TO ENSURE ICE MAKER WILL WORK.
TEST SWITCH -
PRESS AND HOLD FOR 3 SECONDS; THE TEST SWITCH WILL BYPASS THE
TIMER AND TEMPERATURE (THERMISTOR TEMPERATURE -8.C/17.4°F)
AND WILL START TEST SEQUENCE
TEST SEQUENCE BELOW. MONITOR TEST FOR NORMAL CONDITIONS. IF
TEST COMPLETES FULL CYCLE WITHOUT ABNORMAL CONDITION, ICE
MAKER IS WORKING AND OPERATIONAL.
HOME POSITION -
THE ICE TRAY WILL MOVE TO HOME POSITION ONCE TURNED ON THE ICE
MAKER OR AFTER A POWER RESET THEN STARTS THE TWIST PROCESS.
BAIL ARM -
AT THE SAME TIME AS THE TWIST PROCESS, THE BAIL ARM WILL GO
DOWN TO DETECT THE ICE LEVEL.
WATER VALVE -
IF YOU DO NOT WANT TO PUT WATER DIRECTLY INTO THE TRAY, REMOVE
FILL CHUTE AND CATCH WATER WITH A DISPOSABLE CUP.
THE VALVE WILL OPEN FOR 6.8 SECONDS TO DELIVERY A HALF AMOUNT
OF WATER INTO THE TRAY. THE WATER FLOW WILL STOP FOR THE
THREE SECONDS THEN THE VALVE WILL RE-OPEN FOR 6.8 SECONDS TO
COMPLETE THE FILL(117 ). IF THE VALVE COMPLETES THE WATER FILL IN
THE SPECIFIED VOLUME AND TIME, THE ICE MAKER IS WORKING AND IS
FULLY OPERATIONAL.
NOTE: IF THE WATER VALVE OPERATES ONLY ONCE, IT MEANS
SOMETHING IN THE ICE MAKER IS WRONG (COULD BE BAIL ARM OR ICE
MAKER MOTOR).
STAMP
THIS FLOW DIAGRAM IS ONLY FOR TEST SWITCH MODE
NO FULL
ICE MAKER STOP
WATER FILL 6.8 sec
(*60 ml / *2 OZ)
BOTTOM VIEW
REPLACE THE ICE MAKER
RETURN HOME POSITION
PRESS AND HOLD FOR
3 sec (TEST SWITCH)
THERMISTOR CHECK
(OPEN OR CLOSE)
ICE MAKER START TO
TWIST TRAY
DETECTION OF THE ICE
QUANTITY (BAIL ARM
MOVEMENT)
WATER FILL 6.8 sec
(*60 ml / *2 OZ)
WATER FLOW STOP FOR
3 SEC
ICE EJECTION
*MAKE SURE THE ICE MAKER IS ON
BEFORE PRESSING THE TEST SWITCH.
RETURN HOME POSITION
IF THE CONTAINER
IS NOT FULL,
CHECK BAIL ARM
INTERFERENCE
TEST SWITCH
MAIN
SWITCH
MAIN SWITCH - ON
MAIN SWITCH - OFF
END