Buying Guide

Dead-Ending
Sagging Using a Dynamometer
16
COMMON OVERHEAD APPLICATIONS
See Wire Pulling Grip Warnings on the inside cover.
www.kleintools.com
1. Set up the ratchet hoist and Chicago
Grip as shown here.
2. Ratchet the hoist until the cable is
lined up with the dead-end fixture.
3.
After the tension is approximately where
it will need to be after termination,
ratchet the hoist a couple more times
to accommodate for tension loss
after hoist removal. Consult cable
specifications to ensure the maximum
cable tension is not exceeded.
4. When finished, break the tension using the hoist handle, then use either the handle or drum knob to continue releasing the tension.
Splicing
1. Set up ratchet hoist and Chicago
Grips as shown here.
2.
Connect the KN1500PEX Web Strap
Ratchet Hoist to each grip, and
ratchet to the desired tension to
make the splice.
The cable can now be spliced
according to standard work
procedures and material guidelines.
3.
When finished with the splice, break
the tension using the hoist handle, then
use either the handle or drum knob to
continue releasing the tension.
1.
Set up ratchet hoist, Chicago Grip
and dynamometer as shown here.
2. Ratchet the hoist until the
dynamometer displays the desired
tension. Consult conductorspecifications
or company procedures to determine
the appropriate tension.
3. When finished, break the tension
using the hoist handle, then use either
the handle or drum knob to continue
releasing the tension.