Buying Guide

69192
8ZX5
Multimeter Specifications
Multimeter Replacement Fuses
69033
Cat. No. For Use With Fuse Type
69191 MM1000, MM1300, MM2000, MM2300, MM6000 F 11A/1000V
69192 MM1000, MM1300, MM2000, MM2300, MM6000 F 440mA/1000V
69193 MM100 Fuse Kit F10A/500V, F250mA/250V
69194 MM200 Fuse Kit F10A/500V, F400mA/250V
69031 MM300 5x20 200MA 600V
69032 MM300, MM400 6x32 10A 600V
69033 MM400 5x20 500MA 600V
69034 MM600, MM700 10x38 10A 1000V
69035 MM600, MM700 6x32 500MA 1000V
Electrical Test Kit
The MM300 multimeter was developed to withstand daily wear and tear on
the job site, and has a safey rating of CAT III 600V, Class 2, Double insulation
The NCVT-1 has a bright green LED to indicate the tester is working; it
changes to red and warning tones sound when voltage is detected
NCVT-1 has a digitally-controlled ON/OFF power button and auto power-off
feature to conserve and extend battery life
Receptacle tester detects wiring configurations and indicates correct wiring,
open ground, open hot, open neutral, hot/ground reversed; it does not
indicate quality of ground, multiple hot wires, or a combination of defects
Includes visual and audible continuity indicators up to 25Ω
Includes test leads and batteries
69149
Cat. No. Set Contains Weight
69149 0.94 lb
(0.43 kg)
Cat. No. Overall Length Overall Height Overall Width Batteries
MM300 6" (152.4 mm) 1-25/32" (45.2 mm) 3-1/6" (77.8 mm) 2 x AAA
NCVT-1 5-1/2" (139.7 mm) 1" (25.4 mm) 23/32"(18.3 mm) 2 x AAA
Receptical Tester 2-3/4" (69.9 mm) 1" (25.4 mm) 1-1/2" (38.1 mm)
Cat. No. Batteries Standard Included Overall Length Overall Height Overall Width Weight
MM300 2 x AAA CAT III 600V Test Leads and Batteries 6" (152.4 mm) 1-25/32" (45.2 mm) 3-1/6" (77.8 mm) 0.51 lb (0.23 kg)
MM400 2 x AAA CAT III 600V Test Leads, Batteries and Thermocouple 6" (152.4 mm) 1-25/32" (45.2 mm) 3-1/6" (77.8 mm) 0.51 lb (0.23 kg)
MM600 2 x AAA CAT IV 600V Carrying Case, Test Leads, Thermocouple, and Batteries 7" (177.8 mm) 2-3/32" (53.2 mm) 3-35/64" (90.1 mm) 0.90 lb (0.41 kg)
MM700 2 x AAA CAT IV 600V Carrying Case, Test Leads, Thermocouple, Batteries, and Alligator Clips 7" (177.8 mm) 2-3/32" (53.2 mm) 3-35/64" (90.1 mm) 0.90 lb (0.41 kg)
WARNINGS:
To ensure safe operation and service of the tester, follow these instructions. Failure to observe these warnings can result in severe injury or death.
Before each use, verify meter operation by measuring a known voltage or current.
Never use the meter on a circuit with voltages that exceed the category based rating of this meter.
Do not use the meter during electrical storms or in wet weather.
Do not use the meter or test leads if they appear to be damaged.
Ensure meter leads are fully seated, and keep fingers away from the metal probe contacts when making measurements.
Do not open the meter to replace batteries while the probes are connected.
Use caution when working with voltages above 60V DC, or 25V AC RMS. Such voltages pose a shock hazard.
To avoid false readings that can lead to electrical shock, replace batteries if a low battery indicator appears.
Unless measuring voltage or current, shut off and lock out power before measuring resistance or capacitance.
Always adhere to local and national safety codes. Use individual protective equipment to prevent shock and arc blast injury where hazardous live conductors are exposed.
Multimeters
www.kleintools.com
197
Electrical Test & Measurement
AUTO
A
AC
CL200