Instructions / Assembly

4
OTHER MEASUREMENT APPLICATIONS
Maximum Input: 600V AC RMS or 600V DC
Diode Test: Approx. 1mA, open circuit voltage ~3.0V DC
Continuity Check: Audible signal <10Ω, max current 1.5mA
Sampling Frequency: 3 samples per second
Auto Power off: After ~5 minutes of inactivity.
Over Limit: "OL" indicated on display
Polarity: "-" on display indicates negative polarity
Display: 3-3/4 digit, 4000 Count LCD
ELECTRICAL SPECIFICATIONS
Function Range Resolution Accuracy
Capacitance
40.00nF 0.01nF ±(4% + 25 digits)
400.0nF 0.1nF
±(4% + 8 digits)
4.000μF 0.001μF
40.00μF 0.01μF
400.0μF 0.1μF
4.000mF 0.001mF ±(5% + 9 digits)
Maximum Input: 600V AC RMS or 600V DC
Temperature
°F
-40° to 10°F
1
°F
±(1.2% + 7 digits)
11° to 1832°F
±(1.2% + 6 digits)
Temperature
°C
-40° to -12°C
1
°C
±(1.2% + 4 digits)
-11° to 1000°C
±(1.2% + 3 digits)
Maximum Input: 600V AC RMS or 600V DC
Frequency
10Hz to
60kHz
0.001Hz
to 0.01kHz
±(0.1% + 5 digits)
Duty Cycle
0.1% to 99.9%
≤1000kHz
0.1%
±1.5%
(Range: 10% – 90%)
Maximum Input: 600V AC RMS or 600V DC
Voltage Range: 8V to 240V AC RMS
Pulse Width: >0.1ms, must be zero-crossing signal.
ENGLISH
WARNINGS
To ensure safe operation and service of the meter, follow these
instructions. Failure to observe these warnings can result in
severe injury or death.
Before each use verify meter operation by measuring a known
voltage or current.